Description and operating instructions
Industrial Ethernet Rail Switch 2
Hirschmann. Simply a good Connection.
RS2-TX
1
2
P
FAULT
1
3
5
7
DA/STAT
2
4
6
8
0 1
LA1
LA2
LA3
LA4
LA5
LA6
LA7
LA8
1
2
3
4
5
6
7
8
RS2-TX
Order No.
943 686-003
The Rail Switch RS2 has been especially
designed for use in industrial environments.
It supports ETHERNET 10 MBit/s and Fast
ETHERNET 100 MBit/s.
The Rail Switch modules support switched
ETHERNET networks in accordance with
IEEE standard 802.3 using copper technolo-
gy. The switch modules are plugged onto
the standard bar.
The RS2-TX modules have eight 10/100
MBit/s twisted pair ports (RJ45 connectors).
It is possible to connect up to eight data ter-
minal equipments or other network seg-
ments to the 10/100 Mbit/s ports using twi-
sted pair cabling. The ports support auto
negotiation, autopolarity and autocrossing.
Summary of Contents for Belden Hirschmann RS2-TX
Specifications:
|
Accompanying Data:
Belden Hirschmann RS2-TX Network Router PDF Description And Operating Instructions (Updated: Saturday 1st of April 2023 08:38:11 AM)
Rating: 4.4 (rated by 55 users)
Compatible devices: HIRSCHMANN RS2-xTX/xFX EEC Series, HIRSCHMANN RSR20 Series, 400 Family, Hirschman RSPS20, Hirschmann OWL LTE M12, GarrettCom Magnum DX940e, HIRSCHMANN EAGLE40-03, S5500-EI series.
Recommended Documentation:
Belden Hirschmann RS2-TX: Text of Manual, Description And Operating Instructions
(Ocr-Read Version Summary of Contents, UPD: 01 April 2023)
-
1, Description and operating instructions Industrial Ethernet Rail Switch 2 RS2-TX Order No. 943 686-003 The Rail Switch RS2 has been especially designed for use in industrial environments. It supports ETHERNET 10 MBit/s and Fast ETHERNET 100 MBit/s. The Rail Switch modules support switched ETHERNET networks in accordance with IEEE standard 802.3 using copper technolo- gy. …
-
2, 2 The performance features described here are binding only if they have been expressly guaranteed in the contract. We have checked that the contents of the technical publication agree with the hardware and software described. However, it is not possi- ble to rule out deviations completely, so we are unable to guarantee complete agree- ment. However, the details in the technical publicatio…
-
3, 3 CONTROL DRAWING for Industrial ETHERNET Rail Switch 2 and Rail Transceiver 2 Family According to ANSI / ISA 12.12.01-2012 Rev.: 0 Date: 2012-07-13 Document No.: 000163806DNR Page 1 of 1 NON HAZARDOUS LOCATION Power Supply: (Redundant: P1, P2) 24 V DC Relay Contacts: Associated Apparatus: Equipment with nonincendive fi eld wiring 1 HAZARDOUS LOCATION Class…
-
4, 4 Only personnel that have received appropriate training should operate this device or work in its immediate vicinity. The personnel must be fully familiar with all of the warnings and maintenance measures in these operating instructions. Correct transport, storage, and assembly as well as careful operati- on and maintenance are essential in ensuring safe and reliable operation of this device. Us…
-
5, 5 1. Functional description The 10/100BASE-T(X) ports of an RS2-TX represent a terminal connection for the connected LAN segment. You can connect single devices or complete network seg- ments. 1.1 FRAME SWITCHING FUNCTIONS Store and Forward All data received by the RS2-TX from the system bus or at the ports are stored and checked for validity. Invalid and defective frames (…
-
6, 6 3.3 STARTUP PROCEDURE 䡺 You start up the RS2-TX by connecting the supply voltage via the 5-pin terminal block. 3.4 DISMANTLING 䡺 To take the RS2-TX off the ISO/DIN rail, insert a screwdriver horizontally under the housing into the locking slide, pull it (with- out tipping the screwdriver) downwards and lift the RS2-TX upwards. 4. Further support In the event o…
-
7, 7 5. Technical data General data Operating voltage NEC Class 2 power source 24 V DC (-25% +33%) safety extra-low voltage (SELV) (redundant inputs decoupled), 5 A maximum Buffer time min. 10 ms at 24 VDC Potential difference between input Potential difference to input voltage, +24 VDC: 32 V DC voltage and housing Potential difference to input voltage, ground: -32 V DC Current consumption at 2…
-
8, Hirschmann Automation and Control GmbH Stuttgarter Straße 45-51 72654 Neckartenzlingen Germany Tel.: +49 (0)1805 14-1538 Fax: +49 (0)7127 14-1551 E-mail: [email protected] Internet: http://www.hirschmann.com 039 663-001-08-0415
…
Belden Hirschmann RS2-TX: Recommended Instructions
JUICEMAX, WEBCOACH EASYVIEW, NS-13T001, 1-1024UF, Compaq TC1 100
-
43Cisco Systems, Inc. www.cisco.comConnecting the Router to PowerThis section describes how to connect the Cisco 1120 Connected Grid Router to AC and DC power sourceThese topics are discussed: Before You Begin, page 43 AC Power Connection Information, page 45 Connect to AC Power, page 49 Connect to DC Power, page 50 Power Cycling the Router, page 51Before You Be …
1120 10
-
Moxa EtherDevice™ Switch EDS-600 Series Hardware Installation Guide First Edition, August 2009 © 2009 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. Fl.4, No.135, Lane 235, Pao-Chiao Rd. Shing Tien City, Taipei, Taiwan, R.O.C. TEL: +886-2-8919-1230 P/N: 1802006000010 …
EDS-600 Series 20
-
TRENDnet’s TEM100-56R PC Card with XpressPort is the perfect solution for LAN/WAN applications. The 16-bit PC Card adapter combines both 10/100Mbps dual speed Fast Ethernet and the optimal power of V.90/K56Flex dual mode 56K fax/modem capabilities. The TEM100-56R makes it simple to combine numerous communication jobs at the same time. The TEM100-56R lets you dial into any on-line service and …
TEM100-56R 2
-
QFX10002See the complete QFX Series documentation at http://www.juniper.net/techpubs/.To install and configure any model of the Juniper Networks QFX10002 switch, you need:z Either an electric lift or two people to lift the switch into place. An additional person is needed for securing the switch to the rack.z Electrostatic discharge (ESD) grounding strap (not provided).z …
QFX10002 2
-
Quick Start Cisco IP Phone 8800 Series1 Place a Call2 Answer a Call3 Hold4 Transfer5 Conference6 Mute Audio7 Forward All8 Voicemail9 Divert10 Call History11 Directories12 Settings13 Phone Buttons and Hardware14 USB Charging15 Intelligent Proximity16 Tips17 For More InformationNote For best results, print on 8.5inch x 14inch (legal-sized) paper.1 Place a CallTo place a call, pick up …
8800 2
-
Matrix Switch CorporationMSC-1HD1608LProduct Manual1RU 16 input 8 output 3G-SDI Video Router with Button Control PanelRevision 1.7Page 1 of 60 © 2013-2018 Matrix Switch Corporation www.matrixswitchcorp.com …
MSC-1HD1608L 60
-
Mission-Critical Connectivity for VehiclesCOR IBR1700 SeriesPower / GPIO Cable Spare SIM / Modem Door ScrewsWHAT’S INCLUDED: + Cloud-managed + 3 WiFi Radios + Ignition sensing + 9-33 DC voltage input range + Active GPS support + SIM-based auto-carrier selection + Fully ruggedized + Metal housing + Dual-SIM + Integrated 600Mbps LTE/HSPA+ modem + MC400 slot for 2nd modem + …
COR IBR1700 Series 2
-
You’ll be entered into a quarterly drawing for free Cisco Press books by returning this survey! Cisco is dedicated to customer satisfaction and would like to hear your thoughts on these printed manuals. Please visit the Cisco Product Comments on-line survey at www.cisco.com/go/crc to submit your comments about accessing Cisco technical manuals. Thank you for your time.General Information1 …
XR 12404 292
-
Quick start NL | EN | DE6000-0083-01 Adam HAModel 159- 01 [email protected] B.V. Wattstraat 56, 2171 TR SassenheimNLInstallatie » Softwareconguratie zonever-warming, via de webpagina van Adam. » Aansluiten op de warmtebron. » Verbind Adam met het internet. » Controleer de instellingen en vul een postcode in voor de weersvoorspelling.EU-con …
Adam HA 2
-
Operation Manual – SNMP H3C S9500 Series Routing Switches Table of Contents i Table of Contents Chapter 1 SNMP Configuration……………………………………………………………………………………….1-1 1.1 SNMP Overview………………………………………………………………………………………………….. 1- …
S9500 Series 14
Additional Information:
Popular Right Now:
Operating Impressions, Questions and Answers:
1. Functional description
The 10/100BASE-T(X) ports of an RS2-TX
represent a terminal connection for the
connected LAN segment. You can connect
single devices or complete network seg-
ments.
1.1 FRAME SWITCHING FUNCTIONS
Store and Forward
All data received by the RS2-TX from the
system bus or at the ports are stored and
checked for validity. Invalid and defective
frames (> 1.522 byte or CRC error) as well
as fragments (< 64 byte) are discarded. The
RS2-TX forwards the valid frames.
Multi address capability
An RS2-TX learns all source addresses per
port. Only packets with
– unknown addresses
– addresses learnt at this port
– a multi/broadcast address
in the destination address field are sent to
this port.
An RS2-TX learns up to 1,000 addresses.
This becomes necessary if more than one
terminal device is connected to one or more
ports. In this way several independent sub-
networks can be connected to an RS2-TX.
Learnt addresses
An RS2-TX monitors the age of the learned
addresses. The RS2-TX deletes address
entries from the address table which exceed
a certain age (300 seconds).
Note: Restarting deletes the learned
address entries.
Tagging (IEEE 802.1Q)
The IEEE 802.1 Q standard designates the
VLAN tag to be included in a MAC data
frame for the VLAN and prioritizing func-
tions. The VLAN tag consists of 4 bytes (2
bytes tag protocol identifier TPID, 2 bytes
tag control information TCI). It is inserted
between the source address field and the
type field. Data packets with VLAN tag are
transmitted unchanged by the RS2-TX.
1.2 SPECIFIC FUNCTIONS OF THE
TP/TX INTERFACE
Link control
The RS2-TX monitors the connected TP/TX
line segments for short-circuit or interrupt
using regular link test pulses in accordance
with IEEE standard 802.3 10/100BASE-T/TX.
The RS2-TX does not transmit any data to a
TP/TX segment from which it does not
receive a link test pulse.
Note: A non-occupied interface is assessed
as a line interrupt. The TP/TX line to termi-
nal equipment which is switched off is like-
wise assessed as a line interrupt as the de-
energised bus coupler cannot transmit link
test pulses.
Auto polarity exchange
If the receive line pair is incorrectly connec-
ted (RD+ and RD- switched) polarity is auto-
matically reversed.
Autocrossing
The RS2-TX detects the transmit and re-
ceive pairs (MDI, MDI-X). The RS2-TX auto-
matically configures its port for the correct
transmit and receive pins. Consequently it
does not matter whether you connect devi-
ces using a cross-over or straight cable.
1.3 FURTHER FUNCTIONS
AND FEATURES
Reset
The RS2-TX will be reset by the following
action:
– input voltages fall below a threshold
After a reset the following action is carried
through:
– initialization
1.4 DISPLAY ELEMENTS
Equipment status
These LEDs provide information about sta-
tuses which affect the function of the entire
RS2-TX.
P1 – Power 1 (green LED)
– lit:
– supply voltage 1 present
– not lit: – supply voltage 1 less than 9.6 V
P2 – Power 2 (green LED)
– lit:
– supply voltage 2 present
– not lit: – supply voltage 2 less than 9.6 V
FAULT – Failure (red LED)
– lit:
– The indicator contact is
open, i.e. it indicates an
error.
– not lit:
– The indicator contact is
closed, i.e. it does not
indicate an error.
Port Status
These LEDs display port-related informati-
on.
DA/STAT 1 to 8 – Data, Link status
(green/yellow LED)
– not lit:
– no valid link
– lit green:
– valid link
– flashes yellow:– receiving data
1.5 CONTROLS
8-pin DIP switch
Using the 8-pin DIP switch on the RS2-TX
front panel
– the message about the link statuses can
be suppressed by the indicator contact on
a port-by-port basis. Using switches LA1
to LA8, the message about the link status
of ports 1 to 8 is suppressed. State on
delivery: switch position 1 (on), i.e. messa-
ge not suppressed.
0
1
LA1
Port 1
LA2
Port 2
LA3
Port 3
Suppress message
LA4
Port 4
about link status
LA5
Port 5
via indicator contact
LA6
Port 6
LA7
Port 7
LA8
Port 8
Fig. 2: 8-pin DIP switch on RS2-TX
1.6 INTERFACES
10/100 MBit/s connection
Eight 10/100 Mbit Ports (ports 1 to port 8, 8-
pin R45 sockets) on RS2-TX allow terminal
equipment or eight independent network
segments complying with the standards
IEEE 802.3 100BASE-TX / 10BASE-T to be
connected. These ports support autonego-
tiation and the autopolarity function.
The socket casings are electrically connec-
ted to the front panel of the RS2-TX.The pin
configuration complies with MDI-X.
– Pin configuration of the RJ45 socket:
– 1 line pair: pin 3 and pin 6
– 1 line pair: pin 1 and pin 2
– remaining pins: not used.
n.c.
Pin 8
n.c.
Pin 7
TD-
Pin 6
n.c.
Pin 5
n.c.
Pin 4
TD+
Pin 3
RD-
Pin 2
RD+
Pin 1
Fig. 3: Pin configuration of an TP/TX
interface
5pin terminal block
The supply voltage and the indicator
contact are connected via a 5pin terminal
block.
z
Warning!
The RS2-TX equipment is designed
for operation with a safety extra-low
voltage. Thus, they may only be
connected to the supply voltage
connections with SELV circuits with
the voltage restrictions in accordan-
ce with IEC/EN 60950-1.
– Voltage supply: Redundant voltage sup-
plies are supported. Both inputs are
decoupled. There is no load distribution.
With redundant supply, the power pack
supplies the RS2-TX only with the higher
output voltage. The supply voltage is elec-
trically isolated from the housing.
– Indicator contact:
The indicator contact is used to supervise
the functions of the RS2-TX and thus faci-
litates remote diagnosis without manage-
ment software.
Contact interrupt indicates the following
by means of a potential-free indicator
contact (relay contact, closed circuit):
– the failure of at least one of the two
supply voltages.
– a permanent fault in the RS2-TX (inter-
nal 3,3 V DC voltage, supply voltage 1 or
2 < 9.6 V, …).
– the faulty link status of at least one port.
The indication of the link state on the
RS2-TX can be masked on a port-by-port
basis using the DIP switches LA1 to LA8.
State of delivery: there is no link test.
Note: In the case of the voltage supply
being routed without redundancy, the RS2-
TX indicates the failure of a supply voltage.
You can prevent this message by feeding in
the supply voltage through both inputs.
= 0V
Fig. 5: Pin configuration of 5pin terminal
block
Ground connection
The RS2-TX is grounded via a separate
screw connection.
5
Общая информация |
|||||
943-686-003 |
|||||
Интерфейсы |
|||||
8 x 10/100Base-TX (RJ-45), TP |
|||||
Источник питания/сигнальный контакт |
1 подключаемый терминальный блок, 5-пин разъем |
||||
Длина кабелей |
|||||
0 – 100 м |
|||||
Электропитание |
|||||
24В пост. (-25%; +30%) |
|||||
Потребляемый ток (при 24В) |
макс. 290 мА |
||||
Сервисы |
|||||
|
|||||
Резервирование |
|||||
Резервирование питания 24В |
|||||
Условия эксплуатации |
|||||
0°С до +60°С |
|||||
-25°С до +70°С |
|||||
Допустимая влажность (без конденсата) |
10% до 95% |
||||
Физические параметры |
|||||
47мм х 135мм х 111мм |
|||||
DIN-рельс |
|||||
230 г |
|||||
IP20 |
|||||
Помехоустойчивость |
|||||
IEC 60068-2-27 (ударные нагрузки) |
15 g, 11 мс длительность, 18 ударов |
||||
IEC 60068-2-6 (испытания на виброустойчивость) |
|
||||
EN 61000-4-2 (электростатический разряд) |
|||||
EN 61000-4-3 (электромагнитное поле)3 |
10 В/м (80 – 1000 МГц) |
||||
EN 61000-4-4 (резкие подъемы напряжения) |
2 кВ линия питания, 1 кВ линия передачи данных |
||||
EN 61000-4-5 (импульсное перенапряжение) |
Линия питания: 2 кВ (фаза/земля), 1 кВ (фаза/фаза), 1 кВ линия передачи данных |
||||
EN 61000-4-6 (устойчивость к кондуктивному излучению) |
3 В (10 кГц — 150 кГц), 10 В (150 кГц — 80 МГц) |
||||
Класс А |
|||||
Класс А |
|||||
Сертификация |
|||||
Есть |
|||||
Есть |
|||||
Есть |
- Цена и наличие
- Характеристики
- Datasheet PDF
RS2-TX Поставщик
Поставщик
(3 позиции)
Посмотреть все цены компонентов.
обновление
валюта:
Налог может быть рассчитан при выборе юаня.
количество:
Введите количество, чтобы рассчитать общую стоимость.
НДС %
Поставщик | Страна | Наличии | Поставки (день) | MOQ | Валюта | 1+ | 10+ | 100+ | 1K+ | 10K+ | Купить | |
AiPCBA |
China | 17 | Immediate | 1 | USD | 493 | 493 | 493 | 493 | 493 | Купить | |
Allied Electronics |
USA | 0 | Ближайшие | 1 | — | — | — | — | — | Запрос | ||
Chip1Stop |
Japan | 17 | 6 | 1 | USD | 493 | 422 | 422 | 422 | 422 | Купить |
RS2-TX Характеристики
Ошибка обратной связи
Список параметров
Искать альтернативные запчасти
технические
- Напряжение питания
- 24 VDC
другие
- Accessory Type
- Ethernet Switch
- Brand/Series
- RS2 Series
- Mounting Type
- DIN Rail
- Number of Ports
- 8
- Port, Type
- RJ45
- Primary Type
- Ethernet Switch
- Protocol Type
- 10/100 Mbit/s (RJ45)
- Special Features
- Auto-Crossing, Auto-Negotiation, Auto-Polarity
- Supply Voltage
- 24 VDC
- Type
- Unmanaged Switch
соблюдение
- RoHS Комплаенс
-
RoHS Compliant
Продукта обзор
Ethernet Switch Unmanaged 8 RJ45 10/100Mbps Port 943686003 DIN Rail
**RS2-TX**
The RS2 Series of switches offer advanced features such as redundant power inputs and most offer fault relay (triggerable by loss of power and/or port-link). Standard features include 10/100 auto-negotiating and auto-crossing (either patch or cross-over cables will work in the ports), a 0°C to +60°C operating range (-40 to +70°C available), a 24 VDC power input and an average MTBF exceeding 100 years.
Просмотреть все
RS2-TX параметры, RS2-TX datasheet на русском PDF и RS2-TX схема включения, Скачать вручную(2,60KB). Ты можешь использовать RS2-TX даташит на русском поиск датчик RS2-TX характеристики схема подключения и RS2-TX характеристики. понимать RS2-TX схема включения как работает и RS2-TX Описание какие на русском. RS2-TX чем заменить: RS2-TX аналог отечественный и RS2-TX аналоги. FindIC Может предоставить RS2-TX купить, RS2-TX reference manual на русском.