Oregon bar310hg метеостанция инструкция на русском

1. Pressure trend

2. Weather forecast

3. Max / min temperature icon

4. Sensor reception icon

5. Sensor battery low

Weather Station

6. Max / min humidity icon

Model: BAR310HG

7. Clock reception icon

8. Alarm set

USER MANUAL

9. Alarm mode icon

EN

10. Altitude

11. Main unit battery low

INTRODUCTION

12. Temperature trend

Thank you for selecting this Oregon Scientific

TM

weather

13. Temperature

station.

14. Humidity trend

NOTE

Please keep this manual handy as you use your

15. Humidity

new product. It contains practical step-by-step instructions,

as well as technical specifications and warnings you

16. Clock

should know about.

REMOTE SENSOR

CLOCK OVERVIEW

FRONT VIEW

1

1

4

2

5

6

3

1. LED indicator

1. SNOOZE

2. MODE: Change settings / display

GETTING STARTED

3.

: View alarm status; set alarm

BATTERIES

4. MEM: Viewcurrent, maximum and minimum temperature

Insert batteries before first use, matching the polarity (+

5.

/

: Increase / decrease setting; activate /

and -). Press RESET after each battery change.

deactivate clock reception signal.

6 . CH: Switch remote sensor display

BACK VIEW

5

indicates that the batteries are low.

1

NOTE

Do not use rechargeable batteries. We recommended

2

that you use alkaline batteries with this product for longer

3

usage and lithium batteries in temperatures below freezing.

4

WALL MOUNT

Remove the stand at attach as

6

1. RESET: Reset unit to default settings

2. PRESSURE: Select pressure unit; set altitude

1

3. °C / °F: Select temperature unit

4. Battery compartment

5. Wall mount

REMOTE SENSOR

6. Stand

The sensor collects temperature readings approx. every

40 seconds and sends them to the main

LCD DISPLAY

can collect data from up to 3 sensors.

1

10

To set up the sensor:

11

1. Remove the battery door.

2

2. Insert the batteries, matching the polarity (+ / -).

Reset after each battery change.

3. Select a channel. Make sure you use a different

3

12

channel for each sensor.

13

4

14

5

6

15

7

8

9

16

BAR310HG_IM_ENIT_R10.indd 1

4. Close the battery compartment.

5. Place the sensor next to the main unit.

6. Initiate a sensor search on the main unit to start receiving

temperature data from the sensor.

7. Secure the sensor in the desired location using the

table stand or wall mount.

The transmission range may vary depending on many

factors. You may need to experiment with various locations

to get the best results.

Standard Alkaline batteries contain significant amounts of

water. Because of this they will freeze in low temperatures

of approximately -12°C (10°F). Disposable Lithium

1

batteries have a much lower threshold for temperature with

an estimated freezing range of below -30°C (-22°F).

3

Wireless ranges can be impacted by a variety of factors

such as extremely cold temperatures. Extreme cold may

temporarily reduce the effective range between the sensor

and the base station. If the unit’s performance fails due to

low temperature, the unit will resume proper functioning

4

as the temperature rises to within the normal temperature

range (i.e. no permanent damage will occur to the unit due

to low temperatures).

2

5

6

SENSOR DATA TRANSMISSION

The sensor reception icon shows the status.

ICON

DESCRIPTION

1. Wall mount

Main unit is searching for

2. Battery compartment

the sensor(s)

3. Battery compartment

A

channel

cover

found

4. RESET hole

5. CHANNEL switch

Sensor 1 is sending data

The sensor cannot be

and «—.-«

found. Search for the

(temperature area

sensor or check batteries

)

To search for a sensor:

Simultaneously, press and hold MEM and CH for 2

seconds.

NOTE

If the sensor is still not found, check the batteries,

obstructions, and remote unit location.

CLOCK

CLOCK RECEPTION

This product is designed to synchronize its calendar clock

automatically once it is brought within range of a radio

signal:

shown.

DCF-77 generated from Frankfurt, Germany for Central

Europe.

2

The clock collects the radio signals whenever it is within

1500 km (932 miles) of a signal.

RECEPTION SIGNAL

To enable and force a signal search:

Press and hold

for 2 seconds.

unit.

The main unit

To disable the signal reception:

Press and hold

for 2 seconds.

Clock signal reception indicator:

STRONG

WEAK

NO SIGNAL

SIGNAL

SIGNAL

SET CLOCK

If the clock signal reception is enabled and a signal is being

received the clock does not need to be manually set..

1. Press and hold MODE for 2 seconds.

2. Press

or

to change the settings.

3. Press MODE to confirm.

4. The settings order is: time zone offset, 12/24 hr format,

hour, minute, year, day/month format, month, day and

language.

NOTE

The time zone offset can be used to set the clock

up to + / — 9 hours from the received clock signal time. If

you have disabled the clock signal reception (i.e. manually

setting the clock), do not set a value for time zone offset.

NOTE

The language options are English (E), German

(D), French (F), Italian (I), and Spanish (S).

Press MODE to choose between the following display

modes:

• Clock with seconds.

• Clock with weekday.

• Clock with calendar.

• Clock with time zone offset.

ALARM

To set the alarm:

1. Press

to enter alarm mode.

2. Press and hold

for 2 seconds.

3. Press

/

to set hour / minute.

4. Press

to confirm.

indicates alarm is ON.

To activate / deactivate the alarm:

1. Press

to display alarm time.

2. Press

again to turn alarm ON / OFF.

To silence the alarm:

Press SNOOZE to silence it for 8 minutes

OR

Press any key except SNOOZE to turn the alarm off

and activate it again after 24 hours.

has

been

BAROMETER

Barometer readings from the past 24 hours are stored by

the main unit and used to provide weather forecast.

To select barometer measurement unit:

Press PRESSURE to toggle between mb and inHg.

SET ALTITUDE

To ensure barometric readings are reliable set the altitude

to reflect distance from sea level at your position.

1. Press and hold PRESSURE for 2 seconds.

2. Use

and

to set the altitude in 10 M (33 ft)

increments from -100 m (-328 ft) to 2500 m (8202 ft).

3. Press PRESSURE to confirm.

NOTE

The maximum operating altitude for the barometer

and weather forecast is 2500m (8202 ft).

WEATHER FORECAST

This product forecasts the next 12 to 24 hours of weather

within a 30-50 km (19-31 mile) radius based on barometric

pressure trend readings.

ICON

DESCRIPTION

Clear

Partially Cloudy

Cloudy

Rainy

TEMPERATURE AND HUMIDITY

The sensor reception icon indicates the temperature data

displayed:

for indoor temperature

for outdoor temperature (number indicates the

sensor channel displayed)

NOTE

The unit will display indoor humidity unless an

outdoor humidity sensor (sold separately) is selected.

Calendar

To view outdoor sensors temperature readings:

Power

Press CH.

REMOTE UNIT THN132N

To toggle temperature unit:

L x W x H

Press °C / °F.

Weight

To auto-scan between sensors:

Transmission range

Press and hold CH for 2 seconds.

To end auto-scan:

Temperature Range

Press CH.

Power

To toggle between current, minimum and maximum

records for the selected sensor:

Press MEM repeatedly.

NOTE

We recommended that you use alkaline batteries

with this product for longer usage and lithium batteries in

To clear the records:

temperatures below freezing.

Press and hold MEM for 2 seconds.

ABOUT OREGON SCIENTIFIC

TEMPERATURE, HUMIDITY AND

PRESSURE TRENDS

Visit our website (www.oregonscientific.com) to learn more

about Oregon Scientific products such as digital cameras;

The trend icons are based on recent readings.

MP3 players; children’s electronic learning products and

games; projection clocks; health and fitness gear; weather

RISE

STEADY

FALL

stations; and digital and conference phones. The website

also includes contact information for our Customer Care

department in case you need to reach us, as well as

frequently asked questions and customer downloads.

RESET

We hope you will find all the information you need on our

website, however if you’re in the US and would like to

To return to the default settings press RESET.

contact the Oregon Scientific Customer Care department

directly, please visit:

PRECAUTIONS

www2.oregonscientific.com/service/support

This product is engineered to give you years of satisfactory

OR

service if you handle it carefully. Here are a few

Call 1-800-853-8883.

precautions:

• Do not subject the unit to excessive force,

For international inquiries, please visit:

shock, dust, temperature or humidity, which may

result in malfunction, shorter electronic life span,

www2.oregonscientific.com/about/international

damaged battery and distorted parts.

• Do not immerse the unit in water. If you spill liquid over

it, dry it immediately with a soft, lint-free cloth.

EU-DECLARATION OF CONFORMITY

• Do not clean the unit with abrasive or corrosivematerials.

Hereby, Oregon Scientific, declares that the Weather

• Do not tamper with the unit ‘s internal components.

Station (Model BAR310HG) is in compliance with the

Doing so will invalidate the warranty on the unit and

essential requirements and other relevant provisions

may cause unnecessary damage. The unit contains no

of Directive 1999/5/EC.A copy of the signed and dated

user-serviceable parts.

Declaration of Conformity is available on request via our

• Only use fresh batteries as specified in the user’s

Oregon Scientific Customer Service

instructions. Do not mix new and old batteries.

• Due to printing limitations, the displays shown in this

manual may differ from the actual display.

• The contents of this manual may not be reproduced

without the permission of the manufacturer.

COUNTRIES RTTE APPROVAL COMPLIED

• Do not dispose this product as unsorted municipal

waste.Collection of such waste separately for special

treatment is necessary.

NOTE

The technical specifications for this product and

the contents of the user manual are subject to change

without notice.

SPECIFICATIONS

TYPE

DESCRIPTION

MAIN UNIT

86 x 28 x 159.5 mm

L x W x H

(3.38 x 1.02x 6.28in)

156 g (5.5 oz)

Weight

without battery

Temperature unit

°C / °F

-5°C to 50°C

Temperature range.

(23°F to 122°F)

Resolution

0.1°C (0.2°F)

Clock frequency

DCF-77

Synchronization

Auto or disabled

Signal frequency

433 MHz

Clock

Auto or manual (disabled)

Humidity range

25% — 95%

Humidity resolution

1%

Min / Max relative humidity

Memory

and temp.

Alarm duration

2 minutes

Snooze

8 minutes

HH:MM:SS

Clock display

HH:MM: Day of Week

Hour format

12 / 24 hour format

MM / DD or DD / MM

language selectable:

E, I, F, G and S

3 x UM-3 (AA) 1.5 V batteries

96 x 50 x 22 mm

(3.8 x 2.0 x 0.9 in)

48 g (1.7 oz)

30 m (98 ft) unobstructed

-30°C to 60°C

(-22°F to 140°F)

1 x UM-3 (AA) 1.5 V battery

All EU countries, Switzerland CH

and Norway

N

.

2006.7.5 9:33:15 AM

Метеостанции Oregon Scientific BAR310HG — инструкция пользователя по применению, эксплуатации и установке на русском языке. Мы надеемся, она поможет вам решить возникшие у вас вопросы при эксплуатации техники.

Вы можете скачать инструкцию к Oregon Scientific BAR310HG по ссылке ниже, если не хотите ждать загрузки. Если остались вопросы, задайте их в комментариях после инструкции.

«Загружаем инструкцию», означает, что нужно подождать пока файл загрузится и можно будет его читать онлайн. Некоторые инструкции очень большие и время их появления зависит от вашей скорости интернета.

Полезные видео

Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Часто задаваемые вопросы

Как посмотреть инструкцию к Oregon Scientific BAR310HG?

Необходимо подождать полной загрузки инструкции в сером окне на данной странице или скачать кликнув по специальной кнопке.

Руководство на русском языке?

Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью

Как можно распечатать инструкцию?

Скачайте ее по специальной кнопке над формой чтения на ваше устройства и отправьте на печать.

инструкцияOregon Scientific BAR310HG

Weather Station

Model: BAR310HG

USER MANUAL

RGR126_COVER.indd 1 5/11/06 2:29:53 PM

P/N:086L004521-071 REV1

1/88

Посмотреть инструкция для Oregon Scientific BAR310HG бесплатно. Руководство относится к категории Погодные станции, 12 человек(а) дали ему среднюю оценку 8.6. Руководство доступно на следующих языках: английский. У вас есть вопрос о Oregon Scientific BAR310HG или вам нужна помощь? Задайте свой вопрос здесь

Логотип Oregon Scientific
Главная

Не можете найти ответ на свой вопрос в руководстве? Вы можете найти ответ на свой вопрос ниже, в разделе часто задаваемых вопросов о Oregon Scientific BAR310HG.

Аккумулятор в моем устройстве Погодная станция начал ржаветь. Безопасно ли пользоваться устройством?

Инструкция Oregon Scientific BAR310HG доступно в русский?

Не нашли свой вопрос? Задайте свой вопрос здесь

Посмотреть все Oregon Scientific руководства Посмотреть все Oregon Scientific Погодная станция руководства

Смотреть руководство для Oregon Scientific BAR310HG ниже. Все руководства на ManualsCat.com могут просматриваться абсолютно бесплатно. Нажав кнопку «Выбор языка» вы можете изменить язык руководства, которое хотите просмотреть.

MANUALSCAT | RU

Вопросы и ответы

У вас есть вопрос о Oregon Scientific BAR310HG, но вы не можете найти ответ в пользовательском руководстве? Возможно, пользователи ManualsCat.com смогут помочь вам и ответят на ваш вопрос. Заполните форму ниже — и ваш вопрос будет отображаться под руководством для Oregon Scientific BAR310HG. Пожалуйста, убедитесь, что вы опишите свои трудности с Oregon Scientific BAR310HG как можно более детально. Чем более детальным является ваш вопрос, тем более высоки шансы, что другой пользователь быстро ответит на него. Вам будет автоматически отправлено электронное письмо, чтобы проинформировать вас, когда кто-то из пользователей ответит на ваш вопрос.

Задать вопрос о Oregon Scientific BAR310HG

Бренд:
Oregon Scientific
Продукт:
Погодные станции
Модель/название:
BAR310HG
Тип файла:
PDF
Доступные языки:
голландский, английский, немецкий, французский, испанский, итальянский, шведский, португальский

Сопутствующие товары Oregon Scientific BAR310HG

В представленном списке руководства для конкретной модели Цифровой метеостанции — Oregon Scientific BAR310. Вы можете скачать инструкции к себе на компьютер или просмотреть онлайн на страницах сайта бесплатно или распечатать.

В случае если инструкция на русском не полная или нужна дополнительная информация по этому устройству, если вам нужны
дополнительные файлы: драйвера, дополнительное руководство пользователя (производители зачастую для каждого
продукта делают несколько различных документов технической помощи и руководств), свежая версия прошивки, то
вы можете задать вопрос администраторам или всем пользователям сайта, все постараются оперативно отреагировать
на ваш запрос и как можно быстрее помочь. Ваше устройство имеет характеристики:Тип: метеостанция, Измерение температуры (OUT): есть, Диапазон показателей температуры: -30 — 60? C, Измерение влажности: в помещении, в диапазоне 25 — 95%, Барометр: есть, отображение на экране атмосферного давления, Дополнительные функции: прогноз погоды, сохранение температурных значений, часы, будильник, обычный календарь, полные характеристики смотрите в следующей вкладке.

Для многих товаров, для работы с Oregon Scientific BAR310 могут понадобиться различные дополнительные файлы: драйвера, патчи, обновления, программы установки. Вы можете скачать онлайн эти файлы для конкретнй модели Oregon Scientific BAR310 или добавить свои для бесплатного скачивания другим посетителями.

Если вы не нашли файлов и документов для этой модели то можете посмотреть интсрукции для похожих товаров и моделей, так как они зачастую отличаются небольшим изменениями и взаимодополняемы.

Обязательно напишите несколько слов о преобретенном вами товаре, чтобы каждый мог ознакомиться с вашим отзывом или вопросом. Проявляйте активность что как можно бльше людей смогли узнать мнение настоящих людей которые уже пользовались Oregon Scientific BAR310.

goblin

goblin

2017-10-17 19:03:44

ерунда

Геннадий

Геннадий

2018-10-10 17:54:21

желаю купить

vol

Хороший продукт за свою цену.

drag

Датчик слетел

Юрий

работает уже лет 15 проблем нет

Юрий - Казак

Юрий — Казак

2020-12-06 22:17:11

НЕ СВЯЗЫВАЕТСЯ ДАТЧИК С БАЗОВОЙ СТАНЦИЕЙ. Питание новое……

Основные и самые важные характеристики модели собраны из надежных источников и по характеристикам можно найти похожие модели.

Функциональность
Тип метеостанция
Измерение температуры (OUT) есть
Диапазон показателей температуры -30 — 60? C
Измерение влажности в помещении, в диапазоне 25 — 95%
Барометр есть, отображение на экране атмосферного давления
Дополнительные функции прогноз погоды, сохранение температурных значений, часы, будильник, обычный календарь
Особенности
Выносной датчик беспроводной (радиус приема 30 м), макс. число датчиков — 3, в комплекте — 1
Передача данных сбор данных каждые 40 с, частота передачи 433,92 МГц
Питание автономное, батареи типа АА (в комплекте), индикация уровня заряда
Отображение информации цифры и символы, выбор единиц измерения
Настенное крепление есть
Размеры (ВхШхТ) 160х86х28 мм
Дополнительная информация автоматическая синхронизация DСF-77

Здесь представлен список самых частых и распространенных поломок и неисправностей у Цифровых метеостанций. Если у вас такая поломка то вам повезло, это типовая неисправность для Oregon Scientific BAR310 и вы можете задать вопрос о том как ее устранить и вам быстро ответят или же прочитайте в вопросах и ответах ниже.

Название поломки Описание поломки Действие
Сломался Датчик Измерения Температуры
Исчезновение Подсветки Дисплея
Не Измеряется Давление Или Скорость Ветра
Перестали Работать Электронные Часы
Не Срабатывает Будильник
При Кз В Сети Дисплей Светится, Но Никакой Информации Не Отображается.
Не Работает От Сети От Батареек Работает, Шнур Рабочий, Вместе Не Работают. Метеостанции 6 Лет
Не Показывает Внешнюю Температуру На Дисплее Высвечивается Ll.l
Звуковая Индикация Как Отключить
Vantage Pro 2 6163 Отработала 5Лет И Померла. Нет Связи С Консолью. Внутренние Датчики Работают. Можно Как-То Подключить Через Коннектор Com Порта?
Как Заменить Батарейки
Не Показывает Внешнюю Температуру На Дисплее Показывает ———
Периодическое Мигание И Писк Непрерывно Мигают Все Индикаторы Дисплея И Писк 1 Раз В Секунду. При Вынутых Батареях На Дисплее Есть Индикатор Связи И Дом

В нашей базе сейчас зарегестрированно 18 353 сервиса в 513 города России, Беларусии, Казахстана и Украины.

Понравилась статья? Поделить с друзьями:

А вот и еще наши интересные статьи:

  • В 12 витамин инструкция уколы от чего помогает
  • Руководство клиники 21 век
  • Таблетки фильтрум 400мг инструкция по применению
  • Руководство торговой сетью
  • Инструкция по выживанию кто убил янку текст

  • 0 0 голоса
    Рейтинг статьи
    Подписаться
    Уведомить о
    guest

    0 комментариев
    Старые
    Новые Популярные
    Межтекстовые Отзывы
    Посмотреть все комментарии