Weishaupt wg20n 1 c z ln инструкция

Weishaupt WG20 Series Manual

  • Bookmarks

Quick Links

manual

Installation and Operating Instructions

Certified for use in USA / Canada

Conforms to / à UL std 795 (R2013), UL std 295 (R2015) and UL std 296 (R2013)

Certified / certifié CSA std 3.4 (R2009)

Gas Burner WG20…/1-C ZM-LN (W-FM 25)

83055116 • 1/2016-05

loading

Related Manuals for Weishaupt WG20 Series

Summary of Contents for Weishaupt WG20 Series

  • Page 1
    manual Installation and Operating Instructions Certified for use in USA / Canada Conforms to / à UL std 795 (R2013), UL std 295 (R2015) and UL std 296 (R2013) Certified / certifié CSA std 3.4 (R2009) Gas Burner WG20…/1-C ZM-LN (W-FM 25) 83055116 •…
  • Page 2
    83055116 • 1/2016-05 Front cover: WG20…/1-C ZM-LN…
  • Page 3
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) User instructions……………………… 5 Information for user………………….5 1.1.1 Symbols……………………..5 1.1.2 Target group……………………..5 General instructions………………….6 Safety information……………………7 Technical description……………………9 Permissible applications…………………9 Nomenclature……………………9 Basic functions……………………9 3.3.1 Air supply……………………..10 3.3.2 Gas supply…………………….. 10 3.3.3 Electrical components………………….11 3.3.4 Program sequence………………….12 3.3.5 Inputs and outputs………………….
  • Page 4
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) Commissioning and startup………………..31 Conditions………………………31 6.1.1 Connecting measuring device………………32 6.1.2 Air pressure switch presetting………………33 6.1.3 Gas pressure regulator presetting……………..33 6.1.4 Setting values……………………34 Burner setting……………………35 Setting air pressure switch………………..42 Concluding works………………….42 Combustion analysis………………….43 Calculating gas throughput…………………
  • Page 5
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 1 User instructions 1.1 Information for user This installation and operating instruction is part of the equipment and must be kept at the installation at all time. As supplement to this document is the Installation and Operating Instructions for Combustion Manager W-FM 25.
  • Page 6
    Standard Weishaupt burners are designed for indoor use only. For outdoor installa- tions, contact your Weishaupt representative. The installation of any Weishaupt product must be carried out by fully qualified and licensed personnel. The personnel performing the work must be familiar with, and operate within the appli- cable local and national codes, such as CAN/CSA B149.1, 2, 3, CAN/CSA B139-00,…
  • Page 7
    2 Safety information Dangers when using the equipment Weishaupt products are manufactured in accordance with the relevant existing standards and guidelines, and the recognized safety laws. However, improper use of the equipment could endanger the life of the user or third party or result in damage to the plant.
  • Page 8
    • No additional components, which have not been tested for use with the equipment, may be installed. • Use only genuine -weishaupt- replacement and connection parts. • Parts from other manufacturers are not guaranteed to be suitable to meet the necessary operational and safety requirements.
  • Page 9
    Gas burner WG20…/1-C ZM-LN (W-FM 25) 3 Technical description 3.1 Permissible applications Weishaupt gas burner WG20…/1-C ZM-LN is suitable for the following applications: • Installation on heat exchanger. • Warm water boiler . • Steam boiler and hot water boiler.
  • Page 10
    3.3.2 Gas supply Gas train Weishaupt gas and dual fuel burners are equipped as standard with dual safety gas valves, in single or double valve body configuration. * This gas train configuration is for reference only. Actual gas train configuration may…
  • Page 11
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 3 Technical description 3.3.2. Gas supply (cont.) 6 Low gas pressure switch The low gas pressure switch monitors the gas supply pressure. With too low gas pressure, the burner start will be prevented. 7 Additional low gas pressure switch The additional low gas pressure switch monitors the gas pressure downstream of the pressure regulator SKP25.
  • Page 12
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 3 Technical description 3.3.4 Program sequence The burner operating phases are shown on the display, as following: Phase Function TEST After the power supply is switched on, the combustion manager performs a self-test. At call for heat, the air and gas stepping motors drive to the reference position.
  • Page 13
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 3 Technical description W-FM 25 T1 T2 1234 1234 Ionization electrode CLOSED position Air pressure switch Ignition position Temperature/pressure operating ctrl. (On/Off) Low fire Temperature/pressure 2-stage or modulating ctrl. High fire Low gas pressure switch Operating phase High gas pressure switch…
  • Page 14
    Air damper stepping motor Gas butterfly valve stepping motor Slot for analogue module EM3/3 or Fieldbus module EM3/2 External valve LPG (optional) -weishaupt- Burner motor for continuous running blower Burner motor for normal blower operation Ignition unit Double gas valves Not used Bridging plug No.
  • Page 15
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 3 Technical description 3.4 Technical data 3.4.1 Electrical data Burner control Mains voltage / frequency 110 V / 60Hz Power consumption — start max 436 W Power consumption — operation max 336 W Operating current max 3 A…
  • Page 16
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 3 Technical description 3.4.4 Capacity Firing rate Natural gas 119 … 682 MBTU/H Propane 119 … 682 MBTU/H Combustion head WG20-C Capacity graph The capacity graph is based on fuel with low calorific value and tested at sea level. Capacity reduction should be applied depending on the altitude of the installation: approx.
  • Page 17
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 3 Technical description 3.4.5 Dimensions Rp1” –weishaupt– 1-1/4” 14-1/8” (358 mm) (32 mm) 6-1/4” (158 mm) 15-5/8” (397 mm) 5-1/2” (140 mm) — without combustion head extension 9-1/2” (240 mm) — with 3-7/8” (100 mm) combustion head extension 13-3/8”…
  • Page 18
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 4 Installation 4.1 Preparation prior to installation Check burner’s rating plate and capacity graph Check the burner type and rating. The burner rating must be within the operating range of the heating appliance. The ratings given on the burner plate are the minimum and maximum possible firing rates of the burner.
  • Page 19
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 4 Installation 4.2 Burner installation SWITCH OFF POWER FIRST! Prior to the installation, switch off the mains switch and the safety switch. Failure to comply could cause death or serious injury by electric shock. DANGER The burner in its standard version is designed for gas train connection from the right.
  • Page 20
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 4 Installation 4.2.1 Rotate burner by 180° Install the operating interface 1 on the opposite side of the burner’s housing. Install the fixing bracket of the burner housing 3 on the opposite side of the burner’s housing.
  • Page 21
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 4 Installation 4.3 Gas supply Risk of explosion! Gas leaks can lead to the build up of explosive gas — air mixtures. With the presence of an ignition source, these could lead to an explosion. DANGER To avoid accidents, please comply to the following safety information on the gas train installation:…
  • Page 22
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 4 Installation 4.4 Electrical connection SWITCH OFF POWER FIRST! Before the installation, switch off the main switch and the safety switch. Failure to comply could cause death, or serious injury by electric shock. DANGER Burner specific wiring diagram The electrical connection must be made according to the wiring diagram enclosed with…
  • Page 23
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 5 Operation 5.1 Operating interface Function [G] Gas key Select gas butterfly valve stepping motor [-] Minus key Decrease value [+] Plus key Increase value [L/A] Air key Select air damper stepping motor [Enter] Enter key Reset burner;…
  • Page 24
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 5 Operation Operating level The current stepping motor position and/or blower speed can be displayed in the operating level (10 ). Displaying the gas butterfly valve setting: Press [G] key. Displaying the air damper setting: Press [L/A] key.
  • Page 25
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 5 Operation 5.2 Display The display shows the current operating statuses and operating data. 1 Programming level activated 2 Start phase activated 3 Info level activated 4 Stepping motor runs to CLOSED position 5 Stepping motor runs to OPEN position 6 Burner in operation 7 Lockout…
  • Page 26
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 5 Operation 5.2.1 Info mode Burner status and information can be retrieved in the Info mode. Press [Enter] for approx. 0.5 sec. The Info level is activated. Press [Enter] to reach the next information. l,m³…
  • Page 27
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 5 Operation 5.2.2 Service mode The Service mode gives information about: • Stepping motor position of the individual operating points; • The most recent fault; • Flame signal during burner operation. Press [Enter] for approx.
  • Page 28
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 5 Operation 5.2.3 Parameter mode The Parameter mode can only be called up in Stand-by (OFF) mode. Press [+] and [Enter] simultaneously for approx. 2 sec. The Parameter mode is activated. Press [+].
  • Page 29
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 5 Operation 5.2.4 Access mode In the Access mode, the configuration can be adapted relative to the burner type or version. In the Parameter mode, the display mode must be configured to ON, in order to enable access to parameters E0 .
  • Page 30
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 5 Operation 5.3 Linearization During commissioning, it is possible to carry out the linearization of the operating points in gas operation. During linearization, a straight line is generated from the operating point displayed, to P9.
  • Page 31
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 6 Commissioning and startup 6.1 Conditions Commissioning and startup must only be carried out by trained and qualified person- nel. Prior to commissioning, all installation works must be completed and checked. The burner must be installed on the heat exchanger and ready to function with all control and safety devices connected.
  • Page 32
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 6 Commissioning and startup 6.1.1 Connecting measuring devices Measuring device for the ionization current Remove ionization cable from the plug coupling. Connect the current measuring device in series. Ionization current 1 μA Extraneous light detection from: 5 μA…
  • Page 33
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 6 Commissioning and startup 6.1.2 Air pressure switch presetting The air pressure switch presetting is only valid during commissioning. After completing the commissioning, the air pressure switch must be set correctly. Air pressure switch pre-setting prior to commissioning: — approx.
  • Page 34
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 6 Commissioning and startup 6.1.4 Setting values Set the mixing head relative to the required burner capacity. For this, the diffuser setting and the air damper setting should be matched. Determine the diffuser and the air damper settings Do not operate the burner outside its capacity graph.
  • Page 35
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 6 Commissioning and startup 6.2 Burner setting Risk of electric shock Touching the ignition device can lead to electric shock. DANGER Do not touch the ignition device during the ignition process! Check the flame signal during commissioning (see Ch.
  • Page 36
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 6 Commissioning and startup 6.2. Burner setting (cont.) Press [+] key to confirm the factory setting. The combustion manager is preset. 2. Checking the sequence of operation Open the gas isolating valve, reset the low gas pressure switch if necessary. The pressure in the gas train increases.
  • Page 37
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 6 Commissioning and startup 3. Presetting the gas setting pressure If a controlled shutdown or lockout occurs during setting: Briefly press [G] and [L/A] keys simultaneously. Press [+] key. The combustion manager changes to setting level. Open the test point for the setting pressure and connect the pressure measuring device.
  • Page 38
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 6 Commissioning and startup 4. Driving to high fire Press [+] key. The burner drives to the operating point P1. Check the CO content in the flue gas and, if necessary, adjust combustion values via the gas butterfly setting [G].
  • Page 39
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 83055116 • 1/2016-05…
  • Page 40
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 6 Commissioning and startup 8. Performing the linearization process Press [+] key. The burner drives to the operating point P1. Press [Enter] key. The combustion manager switches to linearization mode. Confirm with [+] key.
  • Page 41
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 83055116 • 1/2016-05…
  • Page 42
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 6 Commissioning and startup 6.3 Setting the air pressure switch Switching point must be checked and, if necessary, adjusted during commissioning. Connect the pressure gauge for differential pressure measurement. Start the burner. Check differential pressure over the whole operating range and determine the lowest differential pressure.
  • Page 43
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 6 Commissioning and startup 6.5 Combustion analysis For safe and economic operation of the plant, flue gas measurements are essential when commissioning. The maximum CO content for various gases can be obtained from the gas suppliers. Example: With 15% excess air ( = 1.15) and 12% CO max.
  • Page 44
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 6 Commissioning and startup 6.6 Calculating the gas throughput To provide the correct thermal input to the appliance, the required gas throughput must be determined beforehand. Conversion from standard to operating conditions The calorific value (H) of combustible gases is generally given in relation to the standard barometric conditions.
  • Page 45
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 6 Commissioning and startup 6.7 Subsequent optimization of the operating points For safe and economic operation of the plant, the combustion values can subsequently be corrected. Unplug the bridging plug No. 7 from the combustion manager. The combustion manager drives to stand-by.
  • Page 46
    Installation and Operating Instructions Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) Gas burner WG20…/1-C ZM-LN (W-FM 25) 7 Shutdown 7. Shutdown For breaks in operation: Switch off the power supply to the burner. Close the gas shut off devices. 83055116 •…
  • Page 47
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 8 Maintenance and service 8.1 Notes on maintenance and service Risk of explosion due to leaking gas When dismantling and assembling components which are used in the gas line, ensure that they are correctly cross bonded, aligned, clean and in good condition, and that the fixing screws are correctly tightened.
  • Page 48
    Installation and Operating Instructions Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) Gas burner WG20…/1-C ZM-LN (W-FM 25) 8 Maintenance and service 8.2 Service plan Components Criteria / design lifespan Maintenance or service procedure Blower wheel Soiling Clean Damage Replace Air duct…
  • Page 49
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 8 Maintenance and service 8.3 Removing and re-installing the mixing head Observe the notes on maintenance and servicing (see Ch. 8.1). Risk of explosion due to leaking gas Gas leakage could occur if the gasket 3 is seated incorrectly. Following work at the mixing head, ensure that the gasket is clean and seated correctly.
  • Page 50
    Installation and Operating Instructions Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) Gas burner WG20…/1-C ZM-LN (W-FM 25) 8 Maintenance and service 8 Maintenance and service 8.4 Setting the mixing head Observe the notes on maintenance and servicing (see Ch. 8.1). The distance S1 between the diffuser and the flame tube’s front edge cannot be mea- sured with the burner mounted.
  • Page 51
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 8 Maintenance and service 8.5 Setting the ionization and the ignition electrodes Observe the notes on maintenance and servicing (see Ch. 8.1). Remove the mixing head (see Ch. 8.3). Loosen screw 1. Set the ignition electrode and re-tighten screw 1.
  • Page 52
    Installation and Operating Instructions Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) Gas burner WG20…/1-C ZM-LN (W-FM 25) 8 Maintenance and service 8.6 Service position Observe the notes on maintenance and servicing (see Ch. 8.1). The burner mounted rotated by 180º cannot be placed into service position. Remove the mixing head (see Ch.
  • Page 53
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 8 Maintenance and service 8.7 Removing and re-installing the blower wheel Observe the notes on maintenance and servicing (see Ch. 8.1). Removing Place the housing cover into service position (see Ch. 8.6). Remove the set screw 1 and remove the blower wheel.
  • Page 54
    Installation and Operating Instructions Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) Gas burner WG20…/1-C ZM-LN (W-FM 25) 8 Maintenance and service 8.8 Removing the burner motor Observe the notes on maintenance and servicing (see Ch. 8.1). Remove the blower wheel (see Ch. 8.7). Unplug the plugs number 3 and 11.
  • Page 55
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 8 Maintenance and service 8.9 Removing and re-installing the air damper stepping motor Observe the notes on maintenance and servicing (see Ch. 8.1). Removing Remove the stepping motor plug 4 from the combustion manager. Remove the screws 3.
  • Page 56
    Installation and Operating Instructions Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) Gas burner WG20…/1-C ZM-LN (W-FM 25) 8 Maintenance and service 8.10 Removing and re-installing the angle drive Observe the notes on maintenance and servicing (see Ch. 8.1). Removing Remove the air damper stepping motor (see Ch.
  • Page 57
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 8 Maintenance and service 8.11 Removing and re-installing the gas butterfly valve stepping motor Observe the notes on maintenance and servicing (see Ch. 8.1). Removing Remove the stepping motor plug 1 from the combustion manager. Remove the screws 2.
  • Page 58
    Installation and Operating Instructions Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) Gas burner WG20…/1-C ZM-LN (W-FM 25) 8 Maintenance and service 8.12 Removing and re-installing the gas butterfly valve Observe the notes on maintenance and servicing (see Ch. 8.1). Removing Unscrew the double nipple R1”-1”NPT 3 from the gas butterfly valve.
  • Page 59
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 8 Maintenance and service 8.13 Removing and re-installing the air regulator Observe the notes on maintenance and servicing (see Ch. 8.1). Removing Remove the burner from the appliance. Remove the stepping motor plug 5. Remove the screws 2.
  • Page 60
    Installation and Operating Instructions Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) Gas burner WG20…/1-C ZM-LN (W-FM 25) 8 Maintenance and service 8.14 Replacing the combustion manager Observe the notes on maintenance and servicing (see Ch. 8.1). Unplug all the plugs. Loosen screws 1.
  • Page 61
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 8 Maintenance and service Press [+]. The setting level (parameter E0 ) is displayed. Select value 0 (single fuel burner), if necessary, adjust using [Enter] and [-] keys. Press [+]. E1 is displayed.
  • Page 62
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 8 Maintenance and service 8.15 Replacing the combustion manager’s fuse Observe the notes on maintenance and servicing (see Ch. 8.1). Unplug the connection plug X6 from the combustion manager. Replace the blown fuse with the replacement fuse 1 (6.3 AT). Reconnect the plug X6.
  • Page 63
    Top up the water in the boiler. has tripped. Reset the Low Water safety interlock on the boiler. Notify Weishaupt Customer Service or your Weishaupt representative if this problem occurs repeatedly. 9.1.2 Display showing OFF The following faults may be corrected by the operator: Fault…
  • Page 64
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 9 Faults rectification 9.1.3 Display flashes A burner fault has occurred. The burner is in lockout. The error code is displayed flashing. Read the error code, e.g. A7h. Rectify the cause of the fault (see Ch. 9.2). Resetting Damage could result from incorrect servicing The burner could be damaged.
  • Page 65
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 9 Faults rectification 9.1.4 Detailed fault codes Additional information, which breaks down the error in more detail, can be displayed by pressing a button. The first detailed fault code and the second detailed fault code are relevant only for the following faults: •…
  • Page 66
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 9 Faults rectification 9.2 Fault codes, causes and rectification The following faults must be rectified only by qualified personnel: Fault codes Cause Rectification 02h Internal unit fault Switch off the power supply temporarily. Reset the burner.
  • Page 67
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 9 Faults rectification The following faults must be rectified only by qualified personnel: Fault codes Cause Rectification Switch off via PC software Second detailed fault code: Check Fieldbus address. Invalid Fieldbus address Second detailed fault code: Check configuration at output B4.
  • Page 68
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 9 Faults rectification The following faults must be rectified only by qualified personnel: Fault codes Cause Rectification Operating points were changed Re-adjust the burner. without approval Parameter E3 set incorrectly Check parameter E3 (access level).
  • Page 69
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 9 Faults rectification The following faults must be rectified only by qualified personnel: Fault codes Cause Rectification First detailed fault code: Check freedom of movement of air damper and/or angle drive and gas butterfly valve. Tolerance fault air stepping motor, gas Replace the stepping motor.
  • Page 70
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 9 Faults rectification The following faults must be rectified only by qualified personnel: Fault codes Cause Rectification Flame failure during operation Check burner setting. Check the ionization electrode, replace if necessary. See A7h.
  • Page 71
    Installation and Operating Instructions Gas burner WG20…/1-C ZM-LN (W-FM 25) 9 Faults rectification 9.3 Operating problems The following faults must be rectified only by qualified personnel: Observation Cause Rectification Poor start behaviour of the burner Mixing pressure too high Decrease mixing pressure at ignition position.
  • Page 72
    Oil, gas and dual fuel burners for industrial plant. Control technology / From control panels to complete building management Building systems – at Weishaupt you can find the entire Management spectrum of modern control technology. System (BMS) Future oriented, economical and flexible.

Weishaupt WG20 1-C Z-LN Series Manual

Hide thumbs

Also See for WG20 1-C Z-LN Series:

  • Manual (128 pages)

  • Contents

  • Table of Contents

  • Troubleshooting

  • Bookmarks

Quick Links

Installation and operating instruction

Gas burner WG20…/1-C Z-LN

83054602 1/2020-01

loading

Related Manuals for Weishaupt WG20 1-C Z-LN Series

Summary of Contents for Weishaupt WG20 1-C Z-LN Series

  • Page 1
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 83054602 1/2020-01…
  • Page 2: Table Of Contents

    Installation and operating instruction Gas burner WG20…/1-C Z-LN User instructions …………………. 5 1.1   Target group …………………… 5 1.2   Symbols ……………………..  5 1.3   Guarantee and Liability ……………….. 6 Safety  ………………………..  7 2.1   Designated application ……………….. 7 2.2   When gas can be smelled  ……………… 7 2.3  …

  • Page 3
    Installation and operating instruction Gas burner WG20…/1-C Z-LN Commissioning …………………. 31 7.1   Prerequisite  ……………………. 31 7.1.1   Connect measuring devices ……………. 32 7.1.2   Check gas connection pressure ………….. 33 7.1.3   Check soundness of gas valve train  …………..  34 7.1.4   Purging the gas valve train ……………. 37 7.1.5  …
  • Page 4
    Installation and operating instruction Gas burner WG20…/1-C Z-LN Project planning …………………. 81 12.1   Continuous running fan or post-purge  …………… 81 Spares …………………….. 82 Notes  ………………………  92 Key word index  …………………. 93 4-96 83054602 1/2020-01 La…
  • Page 5: User Instructions

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 1 User instructions 1 User instructions This manual forms part of the equipment and must be kept on site. Translation of original Carefully read the manual prior to working on the unit. operating instructions 1.1 Target group The manual is intended for the operator and qualified personnel.

  • Page 6: Guarantee And Liability

    Weishaupt parts, force majeure, unauthorised modifications made to the unit, the installation of additional components, which have not been tested with the…

  • Page 7: Safety

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 2 Safety 2 Safety 2.1 Designated application The burner is suitable for operation on heat exchangers to EN 303 and EN 676. If the burner is not used on combustion chambers to EN 303 and EN 676, a safety assessment of combustion and flame stability during individual process conditions and of the shutdown limits of the combustion plant has to be carried out and docu- mented.

  • Page 8: Electrical Work

    Carry out soundness test after each service and fault rectification. 2.4 Alterations to the construction of the equipment All conversions require written approval from Max Weishaupt GmbH. No additional components may be fitted, which have not been tested for use with the equipment.

  • Page 9: Product Description

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 3 Product description 3 Product description 3.1 Type key Example: WG20N/1-C Z-LN Type Series: Compact burner Fuel: Gas Size N: Natural Gas F: Liquid Petroleum Gas Ratings size Construction Version Type of control: two stage Mixing head: LowNO 9-96 83054602 1/2020-01 La…

  • Page 10: Serial Number

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 3 Product description 3.2 Serial number The serial number on the name plate identifies the product. This is required by Weishaupt’s customer service department. 1 Name plate Ser.No. 10-96 83054602 1/2020-01 La…

  • Page 11: Function

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 3 Product description 3.3 Function 3.3.1 Air supply Air damper The air damper regulates the air quantity required for combustion. The combustion manager drives the air damper via actuator. At burner shutdown the the actuator automatically closes the air damper. At burner shutdown the air dampers close automatically.

  • Page 12: Gas Supply

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 3 Product description 3.3.2 Gas supply Gas isolating valve 1 The gas isolating valve opens and shuts off the gas supply. Multifunction assembly 8 The multifunction assembly contains: Gas filter 2 The gas filter protects the subsequent valve train components from foreign particles.

  • Page 13: Electrical Components

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 3 Product description High gas pressure switch 6 (optional) The high gas pressure switch monitors the setting pressure. If the setting pressure exceeds the value set, the combustion manager initiates a controlled shutdown. 3.3.3 Electrical components Combustion Manager The combustion manager W-FM is the control unit of the burner.

  • Page 14: Program Sequence

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 3 Product description 3.3.4 Program sequence Pre-purge At heat demand, the actuator drives to full load position after the initialisation time ) has elapsed. The burner motor starts and the air pressure switch reacts. The combustion chamber is pre-purged.

  • Page 15
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 3 Product description W-FM 10 T1 T2 T6 T8 P6 P11 1234 Ionisation electrode Initialisation time (Test): 3 s Air pressure switch Post-purge time: 1.2 s Temperature or pressure regulator Post-purge time: 2.5 s Temperature or pressure regulator full load First test phase: 9.3 s (valve proving valve 1) Low gas pressure switch 2nd test phase: 9.7 s (valve proving valve 2)
  • Page 16: Technical Data

    Temperature during transport / storage –20 … +70 °C relative humidity max 80 %, no dew point Installation elevation max 2000 m Consultation with Weishaupt is required for higher installation elevation. 3.4.4 Fuels Natural Gas E/LL Liquid Petroleum Gas B/P 16-96 83054602 1/2020-01 La…

  • Page 17: Emissions

    (temperature and humidity) medium temperature Combustion chamber dimensions, see Weishaupt Partner Portal / Documents and Applications / Online Applications / NO calculation for burners. Sound levels Dual number noise emission values…

  • Page 18: Rating

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 3 Product description 3.4.6 Rating Combustion heat rating Natural Gas 35 … 200 kW Liquid Petroleum Gas 35 … 200 kW Combustion head WG20-C Capacity graph Capacity graph to EN 676. The capacity data given relates to an installation elevation of 0 m above sea level. For installation elevations above 0 m a capacity reduction of approx. 1 % per 100 m applies.

  • Page 19: Dimensions

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 3 Product description 3.4.7 Dimensions Burner –weishaupt– 32 mm 358 mm 158 mm 397 mm 1 140 mm without combustion head extension 240 mm with combustion head extension (100 mm) 340 mm with combustion head extension (200 mm)

  • Page 20: Weight

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 3 Product description Gas valve train Gas valve Isolating With thermal Without thermal train valve shut off device shut off device 1 W-MF 507 Rp¾ approx. 315 mm approx. 300 mm approx. 320 mm approx.

  • Page 21: Installation

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 4 Installation 4 Installation 4.1 Installation conditions Burner type and capacity graph Burner and heat exchanger must be matched. Check burner type and burner capacity. Installation location Prior to installation ensure that: sufficient space is available for normal and service position [ch. 3.4.7], sufficient combustion air is available, if necessary install ducted air intake, Prepare heat exchanger…

  • Page 22: Burner Installation

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 4 Installation 4.2 Burner installation Only valid in Switzerland When installing and operating the regulations of SVGW, VKF, local and Cantonal regulations and the EKAS guideline (LPG Guideline Part 2) must be observed. The burner in its standard version is designed for valve train connection from the right.

  • Page 23: Rotate Burner By 180° (Optional)

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 4 Installation 4.2.1 Rotate burner by 180° (optional) The following are required for the conversion: actuator adapter with fixing screws, lever with a longer shaft. Remove actuator 1. Disconnect linkage 3. Remove complete lever 2. Fit lever with longer shaft 4 to angle drive.

  • Page 24
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 4 Installation Rotate burner flange 1 180° and mount with flange gasket. Rotate burner 180° and fit screws 2 to burner flange. The aperture between combustion head and refractory should be filled with flame-proof, resilient insulating material (do not make solid).
  • Page 25: Installation

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 5 Installation 5 Installation 5.1 Gas supply Risk of explosion due to leaking gas Gas leaks can lead to a build-up of explosive gas/air mixture. With an ignition source present this can result in an explosion. Install gas supply with care.

  • Page 26: Installing The Gas Valve Train

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 5 Installation 5.1.1 Installing the gas valve train Only in conjunction with W-MF and gas connection pressure > 150 mbar If the gas connection pressure is > 150 mbar, a pressure regulator has to be fitted upstream of the W-MF.

  • Page 27
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 5 Installation Installing the gas valve train from the left To fit the gas valve train to the burner from the left, the burner has to be installed rotated by 180°. To do this, additional conversion measures are required. Move the gas pressure switch prior to installing the multifunction assembly: Remove closing plug 1 and gas pressure switch 3.
  • Page 28: Carry Out Soundness Test Of Gas Supply Line And Vent

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 5 Installation 5.1.2 Carry out soundness test of gas supply line and vent Only the gas supply company or a contract installation company may carry out a soundness test and vent the gas line. 28-96 83054602 1/2020-01 La…

  • Page 29: Electrical Connection

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 5 Installation 5.2 Electrical connection Risk of electric shock Working on the device when voltage is applied can lead to electric shock. Isolate the device from the power supply prior to starting any work. DANGER Safeguard against accidental restart.

  • Page 30: Operation

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 6 Operation 6 Operation 6.1 Operating panel Damage to the combustion manager due to incorrect operation Excessive pressure applied to the illuminated push button can damage the com- bustion manager. Only lightly press illuminated push button. CAUTION The illuminated push button on the combustion manager has the following func- tions:…

  • Page 31: Commissioning

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 7 Commissioning 7 Commissioning 7.1 Prerequisite Commissioning must only be carried out by qualified personnel. Only correctly carried out commissioning ensures the operational safety. Do not operate the burner outside of the capacity graph [ch. 3.4.6]. Prior to commissioning ensure that: all assembly and installation work has been carried out correctly, sufficient combustion air is available, if necessary install ducted air intake…

  • Page 32: Connect Measuring Devices

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 7 Commissioning 7.1.1 Connect measuring devices Measuring device for ionisation current Remove ionisation cable from the plug coupling. Connect current measuring device in series. Ionisation current Extraneous light detection from 0.8 μA Minimum ionisation current 1.5 μA Recommended ionisation current…

  • Page 33: Check Gas Connection Pressure

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 7 Commissioning 7.1.2 Check gas connection pressure Minimum connection pressure Add the combustion chamber pressure in mbar to the minimum connection pres- sure. The connection pressure should not fall below 15 mbar. Determine minimum connection pressure for low pressure installations from table [ch. 7.1.5].

  • Page 34: Check Soundness Of Gas Valve Train

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 7 Commissioning 7.1.3 Check soundness of gas valve train Carry out soundness test: prior to commissioning, after all service and maintenance work. First test phase Second and third test phase Test pressure 100 mbar ±10 % 100 mbar ±10 % Waiting time for pressure equal-…

  • Page 35
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 7 Commissioning Third test phase In the third phase the valve train section from the multifunction assembly up to the gas butterfly valve is tested. Remove mixing head [ch. 9.3]. Fit blanking plate 4. Fit mixing head.
  • Page 36
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 7 Commissioning Test points 1 Pressure into valve 1 2 Pressure between valve 1 and valve 2 3 Pressure after valve 2 36-96 83054602 1/2020-01 La…
  • Page 37: Purging The Gas Valve Train

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 7 Commissioning 7.1.4 Purging the gas valve train Open test point into valve 1 [ch. 7.1.3]. Connect an approved vent hose to the test point. Vent hose must lead to atmosphere. Slowly open gas isolating valve. The gas/air mixture in the valve train vents via the hose to safe atmosphere.

  • Page 38: Preset Pressure Regulator

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 7 Commissioning 7.1.5 Preset pressure regulator Determine setting pressure Add the combustion chamber pressure in mbar to the setting pressure into the gas butterfly valve. Determine setting pressure from the table and note down. The details given for calorific value H relate to 0 °C and 1013 mbar.

  • Page 39
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 7 Commissioning Full load Setting pressure Min. connection pressure into isolating [kW] into gas butterfly valve valve [mbar] (low pressure supply) [mbar] Nominal diameter valve train ¾» 1″ 1″ Multifunction assembly W-MF SE Liquid Petroleum Gas: H = 25.89 kWh/m , d = 1.555…
  • Page 40: Setting Values

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 7 Commissioning 7.1.6 Setting values Set mixing head relative to the combustion heat rating required. For this, the dif- fuser setting and the air damper setting should be matched. Determine diffuser setting and air damper setting Do not operate the burner outside of the capacity graph [ch. 3.4.6].

  • Page 41: Preset Gas And Air Pressure Switch

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 7 Commissioning Set diffuser With dimension X = 0mm the indicating bolt is flush with nozzle assembly cover. Turn screw 1, until dimension X equals the value determined. Set air damper limit switch Check and if necessary adjust position of limit switches ST0, ST1 and ZL.

  • Page 42: Adjusting The Burner

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 7 Commissioning 7.2 Adjusting the burner Risk of electric shock Touching the ignition device can lead to electric shock. Do not touch ignition device during the ignition process. DANGER Check flame signal during commissioning [ch. 7.1.1]. 1.

  • Page 43
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 7 Commissioning 3. Adjust ignition load Check combustion values in ignition load. Set O content of 4 … 5 % via gas butterfly valve screw 1. 4. Adjust full load Select variation 1 or 2 depending on rating selected from setting diagram: Variation 1 Variation 2 Setting diagram…
  • Page 44
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 7 Commissioning 5. Adjust partial load The following steps must only be carried out for two stage operation. For single stage operation continue with step 7. Exit partial load, if the air damper setting has to be adjusted. Any adjustment to the air damper setting for partial load must be made in full load.
  • Page 45
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 7 Commissioning 7. Check start behaviour For single stage operation only If changing the ignition load setting ZL Gas, set limit switch ST1 to the same value as ZL Gas. Switch off and restart burner. Check start behaviour and if necessary correct ignition position.
  • Page 46: Set Pressure Switches

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 7 Commissioning 7.3 Set pressure switches 7.3.1 Set gas pressure switch Low gas pressure switch/valve proving gas pressure switch The switch point must be checked and if necessary adjusted during commission- ing. Connect pressure measuring device to test point 1 of the low gas pressure switch.

  • Page 47: Set Air Pressure Switch

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 7 Commissioning 7.3.2 Set air pressure switch The switch point must be checked and if necessary adjusted during commission- ing. Connect pressure measuring device for differential pressure measurement. Start the burner. Carry out differential pressure measurement across the whole capacity range of the burner and determine the lowest differential pressure.

  • Page 48: Concluding Work

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 7 Commissioning 7.4 Concluding work Check control and safety devices. Remove gas pressure measuring devices and close all test points. Conclude valve proving of gas valve train (fourth test phase) [ch. 7.1.3]. Enter combustion values and settings in the commissioning record and/or test sheet.

  • Page 49: Check Combustion

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 7 Commissioning 7.5 Check combustion Determine excess air Slowly close air damper(s) in the relevant stage, until the combustion limit is reached (CO content approx. 100 ppm). Measure and document O content. Read air number (λ).

  • Page 50: Calculate Gas Throughput

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 7 Commissioning 7.6 Calculate gas throughput Formula symbol Explanation Example values Operating volume [m – Volume measured at gas meter at current pressure and temperature (gas throughput). Standard volume [m – Volume gained by gas at 1013 mbar and 0 °C. Conversion factor –…

  • Page 51: Shutdown

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 8 Shutdown 8 Shutdown For breaks in operation: Switch off burner. Close fuel shut off devices. 51-96 83054602 1/2020-01 La…

  • Page 52: Servicing

    The design lifespan of the components is listed in the service plan [ch. 9.2]. Weishaupt recommends a service contract is entered into to ensure regular in- spections.

  • Page 53
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 9 Servicing Prior to every servicing Inform the operator about the extent of service work to be carried out. Switch off mains switch of installation and safeguard against accidental reactiva- tion. Close fuel shut off devices. Remove cover.
  • Page 54: Service Plan

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 9 Servicing 9.2 Service plan Components Criteria / design lifespan Service procedure Fan wheel Soiling Clean Damage Replace Air duct Soiling Clean Air damper Soiling Clean Air pressure switch Switch point Check 250 000 burner starts or 10 years Replace Ignition cable…

  • Page 55: Removing And Refitting Mixing Head

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 9 Servicing 9.3 Removing and refitting mixing head Observe notes on servicing [ch. 9.1]. Risk of explosion due to leaking gas It is possible for gas to leak out if the gasket 3 is seated incorrectly. Following work on the mixing head, ensure the gasket is clean and seated cor- DANGER rectly, if necessary replace.

  • Page 56: Set Mixing Head

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 9 Servicing 9.4 Set mixing head Observe notes on servicing [ch. 9.1]. The distance between diffuser and flame tube front edge S1 can not be measured with the burner mounted. This is only possible indirectly with the mixing head re- moved, with dimension Lx.

  • Page 57: Set Ionisation And Ignition Electrodes

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 9 Servicing 9.5 Set ionisation and ignition electrodes Observe notes on servicing [ch. 9.1]. Remove mixing head [ch. 9.3]. Undo screw 1. Set ignition electrode and re-tighten screw. Undo screw 2. Set ionisation electrode and re-tighten screw. 57-96 83054602 1/2020-01 La…

  • Page 58: Service Position

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 9 Servicing 9.6 Service position Observe notes on servicing [ch. 9.1]. The burner mounted rotated by 180° cannot be placed into the service position. Remove mixing head [ch. 9.3]. Remove actuator plug 3. Hold housing cover and remove screws 1. Place housing cover into service position 2.

  • Page 59: Remove Burner Motor

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 9 Servicing 9.8 Remove burner motor Observe notes on servicing [ch. 9.1]. Remove fan wheel [ch. 9.7]. Unplug plug number 3 and 11. Disconnect + and — hoses. Undo screws 1 and remove air pressure switch. Hold motor and remove screws 2.

  • Page 60: Removing And Refitting Air Damper Actuator

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 9 Servicing 9.9 Removing and refitting air damper actuator Observe notes on servicing [ch. 9.1]. Removing Remove actuator plug 1 from combustion manager. Remove screws 2. Remove actuator. Refitting Damage to the actuator caused by turning the hub Actuator could be damaged.

  • Page 61: Removing And Refitting Angle Drive

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 9 Servicing 9.10 Removing and refitting angle drive Observe notes on servicing [ch. 9.1]. Removing Remove air damper actuator [ch. 9.9]. Pull drive rod 3 from the gas butterfly valve 8 and remove. Air damper is opened by the force of the spring. Remove frame 4.

  • Page 62: Removing And Refitting Gas Butterfly Valve

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 9 Servicing 9.11 Removing and refitting gas butterfly valve Observe notes on servicing [ch. 9.1]. Removing Remove screws 3. Unscrew flange with double nipple 4. Remove mixing head [ch. 9.3]. Remove drive rod 6. Remove screws 1 and remove gas butterfly valve 2. Refitting Refit gas butterfly valve 2 in reverse order and: ensure correct alignment of drive rod 6 with gas butterfly valve,…

  • Page 63: Removing And Refitting Air Regulator

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 9 Servicing 9.12 Removing and refitting air regulator Observe notes on servicing [ch. 9.1]. Removing Remove bolts 1. Remove burner from heat exchanger [ch. 4.2]. Remove actuator plug 6. Remove bolts 2. Remove intake housing 5. Remove bolts 4.

  • Page 64: Replacing Coil On Multifunction Assembly

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 9 Servicing 9.13 Replacing coil on multifunction assembly Observe notes on servicing [ch. 9.1]. Ensure correct voltage and solenoid number when replacing the solenoid coil. Undo screw 1. Remove cap 2. Replace solenoid coil 3. 64-96 83054602 1/2020-01 La…

  • Page 65: Replace Breather Plug Of Multifunction Assembly

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 9 Servicing 9.14 Replace breather plug of multifunction assembly Observe notes on servicing [ch. 9.1]. A breather plug with integrated filter is fitted to protect the breather orifice against soiling. Replace breather plug 1. 65-96 83054602 1/2020-01 La…

  • Page 66: Removing And Refitting Filter Insert Of Multifunction Assembly

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 9 Servicing 9.15 Removing and refitting filter insert of multifunction assembly Observe notes on servicing [ch. 9.1]. Ensure no dirt enters the multifunction assembly when removing and replacing the filter insert. Removing Remove screws 4. Remove cover 3.

  • Page 67: Replacing The Fuse

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 9 Servicing 9.16 Replacing the fuse Observe notes on servicing [ch. 9.1]. Remove all plugs from the combustion manager. Remove screws from the combustion manager. Remove combustion manager. Replace fuse (T6.3H, IEC 127-2/5). 67-96 83054602 1/2020-01 La…

  • Page 68: Troubleshooting

    Boiler or heating circuit control is not Check function and setting of boiler functioning or has not been set correctly or heating circuit control. Notify your heating contractor or Weishaupt Customer Service if the problem occurs repeatedly. 68-96 83054602 1/2020-01 La…

  • Page 69: Illuminated Push Button Red

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 10 Troubleshooting 10.1.2 Illuminated push button red A burner fault has occurred. The burner is in lockout. Prior to resetting, the error code can be called up and used to control the cause of the fault. Read error code Only 5 seconds after a fault occurred can it be been analysed and read.

  • Page 70
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 10 Troubleshooting Error codes with lockout The following faults must only be rectified by qualified personnel: Fault codes Fault Cause Rectification 2 x flashing No ignition Ignition electrode set incor- Set ignition electrode rectly [ch. 9.5] No flame,…
  • Page 71
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 10 Troubleshooting The following faults must only be rectified by qualified personnel: Fault codes Fault Cause Rectification Flashing 6 times Actuator does not reach tar- Actuator plug unplugged Plug in actuator plug get position within 10 Actuator defective Check actuator, replace if…
  • Page 72
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 10 Troubleshooting The following faults must only be rectified by qualified personnel: Fault codes Fault Cause Rectification Flashing 12 times Valve 1 leaking Gas valve train leaking Check soundness of gas valve train [ch. 7.1.3] Valve proving fault Gas pressure switch set in- Set gas pressure switch…
  • Page 73: Illuminated Push Button Flashes

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 10 Troubleshooting 10.1.3 Illuminated push button flashes An irregularity is present. The burner does not go to lockout. Once the fault has been rectified, the error code ceases. Error codes without lockout The following faults must only be rectified by qualified personnel: Fault codes Cause…

  • Page 74: Technical Documentation

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 11 Technical documentation 11 Technical documentation 11.1 Wiring diagram For special version observe wiring diagram supplied. W-FM 10 X5:1 X3:11 X4:1 L PE N T1 T2 S3 B4 B5 T6 T7 T8 L PE N Air pressure switch Temperature or pressure regulator…

  • Page 75
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 11 Technical documentation X3:3 X3:4 X3:13 X3:12 X3:5 X3:1 X3:6 P11.1 L1 PE N PE L1 L2 1 PE 2 3 Flame sensor Low gas pressure switch/valve proving gas pressure switch Motor capacitor double gas valve External valve LPG (optional) Burner motor…
  • Page 76: Conversion Table Unit Of Pressure

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 11 Technical documentation 11.2 Conversion table unit of pressure Pascal 0.1 mbar 0,01 0.00001 1 mbar 0.0001 10 mbar 1 000 0.001 100 mbar 10 000 0,01 1 bar 100 000 1 000 10 bar 1 000 000 10 000…

  • Page 77: Appliance Categories

    5.1.2, table 5 are used to provide the evidence of service performance of the burner during type testing. As -weishaupt- gas and dual fuel burners fulfil this requirement completely, the ap- pliance category, as well as the test gases used with the permissible connection pressure range, are listed on the name plate when labelling the burner to point 6.2 .

  • Page 78
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 11 Technical documentation Alternative appliance category to I2R Country of destination Appliance category Test gas Connection pressure mbar AL (Albania) G 20 AT (Austria) G 20 BA (Bosnia) G 20 BE (Belgium) I2E+, I2N, I2E(R)B G 20 + G 25 Pressures…
  • Page 79
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 11 Technical documentation Alternative appliance category to I3R Country of destination Appliance category Test gas Connection pressure mbar AL (Albania) I3+, I3P, I3B G 30 + G 31 Pressures 28 — 30 / 37 AT (Austria) I3B/P, I3P G 30 + G 31…
  • Page 80
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 11 Technical documentation Alternative appliance category to II2R/3R Country of destination Appliance category Test gas Connection pressure Test gas Connection pressure mbar mbar AL (Albania) II2H3+, II2H3P G 20 G 31 AT (Austria) II2H3B/P, II2H3P G 20 G 30 + G 31…
  • Page 81: Project Planning

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 12 Project planning 12 Project planning 12.1 Continuous running fan or post-purge Fire hazard due to failure of the combustion air fan Failure of the combustion air fan (e.g. due to a power failure or defective motor) during operation with continuous running fan or increased post-purge may result in back radiation or hot flue gases flowing back into the burner housing.

  • Page 82: Spares

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 13 Spares 13 Spares 1.01 1.19 1.16 1.06 1.17 1.08 1.07 1.18 1.03 1.02 1.17 1.15 1.04 1.11 1.15 1.09 1.12 1.05 1.12 1.10 1.14 1.13 82-96 83054602 1/2020-01 La…

  • Page 83
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 13 Spares Pos. Description Order No. 1.01 Cover complete 241 210 01 112 1.02 Screw M8 x 15 142 013 01 157 1.03 Washer 7 x 18 430 016 1.04 Burner housing 241 210 01 012 1.05 Intake housing complete…
  • Page 84
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 13 Spares 2.21 2.11 2.10 2.12 2.08 2.13 2.14 2.22 2.09 2.25 2.24 2.02 2.15 2.06 2.01 2.20 2.16 2.18 2.06 2.19 2.23 2.17 2.07 2.03 2.05 2.26 2.04 2.28 2.27 84-96 83054602 1/2020-01 La…
  • Page 85
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 13 Spares Pos. Description Order No. 2.01 Motor ECK 04/A-2 230 V / 50 Hz 652 084 2.02 Screw M5 x 12 409 278 2.03 Capacitor set 713 476 2.04 Pressure switch LGW 10 A2 1 — 10 mbar 691 370 2.05 Connection flange for LGW…
  • Page 86
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 13 Spares 3.01 3.03 3.05 3.04 3.02 3.08 3.09 3.06 3.07 3.19 3.18 3.17 3.17 3.13 3.10 3.14 3.15 3.12 3.16 3.11 3.21 3.22 3.20 86-96 83054602 1/2020-01 La…
  • Page 87
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 13 Spares Pos. Description Order No. 3.01 Mixing head WG20N/1-C cpl. (Natural Gas) – Standard 232 210 14 052 – extended by 100 mm* 230 210 14 072 – extended by 200 mm* 230 210 14 082 –…
  • Page 88
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 13 Spares 4.07 4.08 4.10 4.05 4.09 4.04 4.06 4.01 4.03 4.02 4.13 4.11 4.12 4.14 4.15 88-96 83054602 1/2020-01 La…
  • Page 89
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 13 Spares Pos. Description Order No. 4.01 Combustion manager W-FM10 230 V / 50/60 Hz 600 475 – Micro fuse T6.3H, IEC 127-2/5 483 011 22 457 4.02 Adapter ring 22 x 4 for extension 600 358 4.03 Reset button extension AGK20.19…
  • Page 90
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 13 Spares 5.01 5.08 5.05 5.02 5.07 5.03 5.06 5.04 5.06 5.05 5.09 5.11 5.10 5.13 5.15 5.14 5.12 90-96 83054602 1/2020-01 La…
  • Page 91
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 13 Spares Pos. Description Order No. 5.01 Double nipple R1 x 80 with Loctite 139 000 26 747 5.02 Elbow A1-1-Zn-A 453 123 5.03 Double nipple R1 x 50 with Loctite 139 000 26 737 5.04 Flange W-MF –…
  • Page 92: Notes

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 14 Notes 14 Notes 92-96 83054602 1/2020-01 La…

  • Page 93: Key Word Index

    Installation and operating instruction Gas burner WG20…/1-C Z-LN 15 Key word index 15 Key word index Electrostatic discharge………… 8 Emission……………. 17 Actuator…………….. 60 Emission class ………….. 17 Air damper ………. 11, 40, 60, 61, 63 Error code……………. 69 Air number ……………. 49 Error codes………….. 70, 73 Air pressure ……………. 50 Errors ……………… 70 Air pressure switch………….

  • Page 94
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 15 Key word index Installation………….. 21, 22 Installation elevation ………..  16, 18 Refractory ……………. 21 Installation location …………. 21 Remote reset……………. 29 Installation position …………. 25 Reset……………… 69 Intake housing………….. 63 Reset button…………….. 30 Ionisation current………….. 32 Residence time………….. 15 Ionisation electrode …………  13, 57 Isolating valve……………
  • Page 95
    Installation and operating instruction Gas burner WG20…/1-C Z-LN 15 Key word index Weight………………. 20 Wiring diagram ………….. 74 95-96 83054602 1/2020-01 La…
  • Page 96
    Max Weishaupt GmbH · 88475 Schwendi Weishaupt close by? Addresses, telephone numbers etc. can be found at www.weishaupt.de We reserve the right to make changes. All rights reserved. The complete program: Reliable technology and prompt, professional service W Burners up to 570 kW…

Горелка газовая Weishaupt WG20 N/1-C Z-LN, 35-200кВт, 1″

  • Артикул: 232 213 34
  • Производитель: Weishaupt
  • Страна происхождения: Германия

— мощность 35-200 кВт;
— одно- и двухступенчатая;  
— основное топливо — природный газ;
— воздушная заслонка — c сервоприводом;
— газовый мультиблок тип 507, 3/4

  • Базовая цена
Диапазон работы в кВт 35-200
Расход топлива в м3/час
Мощность котла, КПД=92%  в кВт 32,2-184
Напряжение           ~ 50 Гц 230 В
Мощность электродвигателя в Вт 210
Режим работы   одно- и двухступенчатый 
Запальный трансформатор W-ZG01
Блок управления (менеджер горения) W-FM 10
Потребление тока старт. max/экспл.  —

Ключ краткого обозначения:

  • W  Горелка Weishaupt типоразмера W
  • G/L   Газ/жидкое топливо
  • 5/10/20/30-40   Типоразмер
  • N/F природный газ E и LL / сжиженный газ B/P
  • 1/2/3/4   Индекс смесительного устройства
  • A/B/C   Без модификации/ первая/ вторая модификация и т.д.
  • LN   одноступенчатая
  •    Двухступенчатая
  • ZM  Плавно-ступенчатая или модулируемая
  • ZM-LN   с низким выбросом оксидов азота (LowNOx)

Комплектация Weishaupt WG:

  • Газовый мультиблок
  • Шаровой кран
  • Встроенная звукоизоляция
  • Фланец
  • Электродвигатель переменного тока
  • Высокопроизводительный вентилятор
  • Датчик контроля давления воздуха
  • Смесительное устройство и горелочная труба
  • Трансформатор зажигания с комбинированным электродом
  • Кожух горелки
  • Крепежные детали с уплотнителем фланца

Габаритные размеры газовых горелок  Weishaupt WG20 N/1-C Z-LN

WG 20.png

Полезная информация:

  • Инструкция по монтажу и эксплуатации weishaupt WG20-1-C Z-LN документ PDF

Типоряд W 5—40

— W5
— W10
— W20
— W30
— W40

Типоряд WM monarch

— WM 10
— WM 20
— WM 30
— WM 50

Типоряд 30—70

— 30-70

Типоряд WK

— WK 40-80

Типоряд WKmono

— WKmono 80

Типоряд W 5—40

W5

Газовые горелки

Постоянная работа двигателя, горелки WG(L). Инструкция по монтажу, 5515RUS, 1/2019-04
Система забора воздуха для горелок Weishaupt. Инструкция по монтажу, 5479RUS, 1/2017-06
Внимание! Дополнительный лист. План проведения техобслуживания газовых горелок WG 5 … 40, 5393 RUS-1/2017
WG 5. Горелки газовые, исполнение LN, 0512RUS, 1/2020-01
WG 5. Горелки газовые, руководство по обслуживанию, 1296RUS-1/02

Жидкотопливные горелки

WL5/1-B H-2LN. Жидкотопливные горелки, 0584RUS — 1/2016-08
WL5/1-B исп. H. Горелки жидкотопливные, руководство по монтажу и эксплуатации, 2721RUS-1/2019-03
Постоянная работа двигателя, горелки WL. Инструкция по монтажу, 5516 RUS 1/2017-11
Система забора воздуха для горелок Weishaupt. Инструкция по монтажу, 5479RUS, 1/2017-06
WL5/2-B, Жидкотопливные горелки, 2722RUS, — 1/2019-04
WL5/1-B, Жидкотопливные горелки, 2720RUS, 1/2016-08
Внимание! Дополнительный лист. План проведения техобслуживания ж/т горелок WL 5 … 40, 5394 RUS-1/2017
WL5/1-B-H. Горелки дизельные, исполнение 2LN. Без насадки на пламенную голову для реверсивных котлов, 1644RUS-1/04
WL5-A-Н. Горелки дизельные, исполнение 1LN, 522RUS-1/01
WL 5. Горелки дизельные, исполнение стандартное и с подогревом топлива, 511RUS-1/01
WL 5. Горелки дизельные, исполнение стандартное и с подогревом, 583RUS-1/03
WL 5. Горелки дизельные, исполнение H-2LN, 584RUS-1/03

W10

Газовые горелки

Постоянная работа двигателя, горелки WG(L). Инструкция по монтажу, 5515 RUS 1/2017-11
Система забора воздуха для горелок Weishaupt. Инструкция по монтажу, 5479RUS, 1/2017-06
Арматура с W-MF для давления на входе > 150 мбар, 5109 1/2016-04
Внимание! Дополнительный лист. План проведения техобслуживания газовых горелок WG 5 … 40, 5393 RUS-1/2017
WG10…/0-D. Горелки газовые, исполнение ZM-LN, 3009 RUS-1/16
WG 10…/1-D. Горелки газовые, исполнение ZM-LN, 554RUS-1/16
WG10…/1-D. Горелки газовые, исполнение LN, 0587RUS, 1/2020-01
WG10…/1-D. Горелки газовые, исполнение Z-LN, 0553RUS, 1/2020-01

Жидкотопливные горелки

WL10/1-D 1LN . Жидкотопливные горелки, 2993RUS,1/2019-04
WL10/2-D 1LN . Жидкотопливные горелки, 2994RUS, 1/2019-04
WL10/2-D . Жидкотопливные горелки, 2925RUS, 1/2019-04
Постоянная работа двигателя, горелки WL. Инструкция по монтажу, 5516 RUS 1/2017-11
WL10/2-D исп. Z. Жидкотопливные горелки, 2927RUS, 1/2019-04
WL10/3-D исп. Z. Жидкотопливные горелки, 2928RUS, 1/2019-04
WL10/3-D. Жидкотопливные горелки, 2926RUS, 1/2019-04
Система забора воздуха для горелок Weishaupt. Инструкция по монтажу, 5479RUS, 1/2017-06
Внимание! Дополнительный лист. План проведения техобслуживания ж/т горелок WL 5 … 40, 5394 RUS-1/2017

W20

Газовые горелки

WG 20…/1-C. Горелки газовые, исполнение Z-LN, 0546RUS 1/2020-01
Постоянная работа двигателя, горелки WG(L). Инструкция по монтажу, 5515 RUS 1/2017-11
Система забора воздуха для горелок Weishaupt. Инструкция по монтажу, 5479RUS, 1/2017-06
Арматура с W-MF для давления на входе > 150 мбар, 5109 1/2016-04
Внимание! Дополнительный лист. План проведения техобслуживания газовых горелок WG 5 … 40, 5393 RUS-1/2017
WG 20…/1-С. Горелки газовые, исполнение ZM-LN, 551RUS-1/16
WG 20…/1-C. Горелки газовые, исполнение LN, 2408RUS-1/04

Жидкотопливные горелки

WL 20/2-C исполнение Z. Жидкотопливные горелки, 3077RUS, 1/2019-04
WL20/1-C Z. Жидкотопливные горелки, 3076RUS — 1/2019-04
Постоянная работа двигателя, горелки WL. Инструкция по монтажу, 5516 RUS 1/2017-11
WL20/1-C Z исполнение 1LN, Жидкотопливные горелки, 559RUS-1/2017-05
Система забора воздуха для горелок Weishaupt. Инструкция по монтажу, 5479RUS, 1/2017-06
WL 20/2-С. Горелки дизельные, одноступенчатые, 3021RUS — 1/2016-08
Внимание! Дополнительный лист. План проведения техобслуживания ж/т горелок WL 5 … 40, 5394 RUS-1/2017
WL 20. Горелки дизельные, исполнение Z, двухступенчатые, 549RUS-1/01
WL 20/1-С. Горелки дизельные, одноступенчатые, 3020RUS — 1/2019-04

W30

Газовые и комбинированные горелки

WG30…/1-C ZM-LN. Горелки газовые, руководство по монтажу и эксплуатации, 2999RUS-1/2019-02
Постоянная работа двигателя, горелки WG(L). Инструкция по монтажу, 5515 RUS 1/2017-11
Система забора воздуха для горелок Weishaupt. Инструкция по монтажу, 5479RUS, 1/2017-06
Арматура с W-MF для давления на входе > 150 мбар, 5109 1/2016-04
Внимание! Дополнительный лист. План проведения техобслуживания газовых горелок WG 5 … 40, 5393 RUS-1/2017
Внимание! Дополнительный лист. План проведения техобслуживания комбинированных горелок WGL 30 … 40, 5395 RUS-1/2017
WGL30/1-C исп. ZM. Горелки комбинированные, руководство по монтажу и эксплуатации, 2602RUS-1/2019-02
WG30/1 С, WG 40/1 А. Горелки газовые, исполнение ZM LN 489RUS 1/04
WGL30. Горелки комбинированные с менеджером горения W-FM24, 2602RUS-1/2011
WG 30 и WG 40. Горелки газовые, исполнение ZM-LN, с частотным регулированием двигателя, 552RUS-1/02

Жидкотопливные горелки

WL 30 Z-C исполнения 4LN. Жидкотопливные горелки, руководство по монтажу и эксплуатации, 2988RUS, 2/2019-05
Постоянная работа двигателя, горелки WL. Инструкция по монтажу, 5516 RUS 1/2017-11
Система забора воздуха для горелок Weishaupt. Инструкция по монтажу, 5479RUS, 1/2017-06
Внимание! Дополнительный лист. План проведения техобслуживания ж/т горелок WL 5 … 40, 5394 RUS-1/2017
WL 30 Z-C с WFM 25. Жидкотопливные горелки, руководство по монтажу и эксплуатации, 2979RUS 3/2019-11
WL 30Z-C. Горелки дизельные, на технологической установке, 1976RUS-1/2010

W40

Газовые и комбинированные горелки

Постоянная работа двигателя, горелки WG(L). Инструкция по монтажу, 5515 RUS 1/2017-11
Система забора воздуха для горелок Weishaupt. Инструкция по монтажу, 5479RUS, 1/2017-06
Арматура с W-MF для давления на входе > 150 мбар, 5109 1/2016-04
Внимание! Дополнительный лист. План проведения техобслуживания газовых горелок WG 5 … 40, 5393 RUS-1/2017
Внимание! Дополнительный лист. План проведения техобслуживания комбинированных горелок WGL 30 … 40, 5395 RUS-1/2017
WG40…/1-A исп. ZM-LN с WFM 25, Газовые горелки, руководство по монтажу и эксплуатации, 3000 1/2019
WGL40/1-A ZM. Горелки комбинированные, руководство по монтажу и эксплуатации, 2734RUS-1/2019-02
WG 30 и WG 40. Горелки газовые, исполнение ZM-LN, с частотным регулированием двигателя, 552RUS-1/02
WG30/1-С, WG40/1-А. Горелки газовые, исполнение ZM-LN, 489RUS-1/04

Жидкотопливные горелки

WL40Z-A 1LN . Жидкотопливные горелки, 2989RUS, 2/2019-05
Постоянная работа двигателя, горелки WL. Инструкция по монтажу, 5516 RUS 1/2017-11
Система забора воздуха для горелок Weishaupt. Инструкция по монтажу, 5479RUS, 1/2017-06
WL 40 Z-А. Жидкотопливные горелки, 2980RUS, 3/2019-11
Внимание! Дополнительный лист. План проведения техобслуживания ж/т горелок WL 5 … 40, 5394 RUS-1/2017
WL 40Z-C. Горелки дизельные, на технологической установке, 1977RUS-1/2010

Типоряд WM monarch

WM 10

WM-G10/1-A исп. ZM с W-FM 50. Горелки газовые, руководство по монтажу и эксплуатации, 2618RUS-1/2018
WM-G10/1-A исп. ZM-LN с W-FM 50. Горелки газовые, руководство по монтажу и эксплуатации, 2637RUS-1/2011
WM-G10/1-A исп. ZM c W-FM 100/200. Горелки газовые, руководство по монтажу и эксплуатации, 2427RUS-1/2018
WM-G10/1-A исп. ZM-LN с W-FM 100/200. Горелки газовые, руководство по монтажу и эксплуатации, 2431RUS-1/2011
WM-G10/1-A исп. ZMI с W-FM 100/200. Горелки газовые, руководство по монтажу и эксплуатации, 2651RUS-1/2011
WM-G10/2-A исп. ZM с W-FM 50. Горелки газовые, руководство по монтажу и эксплуатации, 2495RUS-1/2019
WM-G10/2-A исп. ZM-LN с W-FM 50. Горелки газовые, руководство по монтажу и эксплуатации, 2500RUS-1/2011
WM-G10/2-A исп. ZM с W-FM100. Горелки газовые, руководство по монтажу и эксплуатации, 2428RUS-1/2019
WM-G10/2-A исп. ZM-LN с W-FM 100. Горелки газовые, руководство по монтажу и эксплуатации, 2432RUS-2/2020-05
WM-G10/2-A исп. ZMI с W-FM 100. Горелки газовые, руководство по монтажу и эксплуатации, 2652-1/2011
WM-G10/3-A исп. ZM с W-FM 50. Горелки газовые, руководство по монтажу и эксплуатации, 2496RUS-1/2019
WM — G10/3-A / ZM-LN с W-FM 50. Горелки газовые, руководство по монтажу и эксплуатации, 2501RUS — 1/2019-07
WM — G10/3-A исп. ZM с W-FM 100/200. Газовые горелки, руководство по монтажу и эксплуатации, 2429RUS — 1/2019-01
WM — G10/3-A / ZM-LN с W-FM 100/200. Горелки газовые, руководство по монтажу и эксплуатации, 2433RUS — 1/2019-07
WM-G10/3-A исп. ZMI c W-FM 100/200. Горелки газовые, руководство по монтажу и эксплуатации, 2653RUS- 1/2011
WM-G10/4-A исп. ZM с W-FM 50. Горелки газовые, руководство по монтажу и эксплуатации, 2497RUS-1/2019
WM-G10/4-A исп. ZM с W-FM 100. Горелки газовые, руководство по монтажу и эксплуатации, 2430RUS-1/2011
WM-G10/4-A исп. ZMI с W-FM 100/200. Горелки газовые, руководство по монтажу и эксплуатации, 2654RUS-1/2011
WM-GL10/1-A исп. ZM-T с W-FM 100. Горелки комбинированные, руководство по монтажу и эксплуатации, 2461RUS-1/2007
WM-GL10/2-A исп. ZM-T с W-FM 100. Горелки комбинированные, руководство по монтажу и эксплуатации, 2462RUS-1/2009
WM-GL10/2-A исп. ZM-R с W-FM 54. Горелки комбинированные, руководство по монтажу и эксплуатации, 2657RUS-1/2012
WM-GL10/2-A исп. ZM-R с W-FM 100. Горелки комбинированные, руководство по монтажу и эксплуатации, 2464RUS-1/2020-06
WM-GL10/3-A исп. ZM-T с W-FM 100. Горелки комбинированные, руководство по монтажу и эксплуатации, 2463RUS-1/2006
WM — GL10/3-A исп. ZM-R с W-FM 100/200. Комбинированная горелка, руководство по монтажу и эксплуатации, 2465RUS — 1/2019-02
WM-GL10/1-A исп. ZM-T с W-FM 54. Горелки комбинированные , руководство по монтажу и эксплуатации, 2614RUS-1/2009
WM-GL10/2-A исп. ZM-T с W-FM 54. Горелки комбинированные, руководство по монтажу и эксплуатации, 2615RUS-1/2012
WM-GL10/3-A исп. ZM-T с W-FM 54. Горелки комбинированные , руководство по монтажу и эксплуатации, 2616RUS-1/2017
WM — GL 10/4-A / ZM-T с W-FM 54. Горелки комбинированные, руководство по монтажу и эксплуатации, 2617RUS-1/2019-02
WM — G10/3-A исп. ZM-3LN multiflam® с W-FM 50. Горелки газовые, руководство по монтажу и эксплуатации, 2589RUS-1/2018-11
WM-L10/4-A исп.T с W-FM 50. Горелки жидкотопливные, руководство по монтажу и эксплуатации, 2491RUS-1/2019-12

WM 20

WM — S20/2-A / T с W-FM 50. Горелки жидкотопливные, руководство по монтажу и эксплуатации,3132RUS-1/2018-11
WM-G 20/3-A исп. ZM-LN с WFM 50. Горелки газовые, руководство по монтажу и эксплуатации, 2509RUS-1/2019-05
WM-L 20/1-A исп. T c W-FM 50. Горелки жидкотопливные, руководство по монтажу и эксплуатации, 2477RUS-1/2020-02
WM — G 20/2-A исп. ZMI c W-FM 100/200. Горелки газовые, руководство по монтажу и эксплуатации, 2788RUS-1/2018-05
WM — GL20/2-A / ZM-R (W-FM 100/200), Горелки комбинированные, руководство по монтажу и эксплуатации, 2487RUS, 1/2018-10
WM — GL 20/3-A / ZM-R (W-FM 54), Горелки комбинированные, руководство по монтажу и эксплуатации, 2639RUS, 1/2018-05
WM — GS20/3-A / ZM-R (W-FM 100/200), Горелки комбинированные, руководство по монтажу и эксплуатации, 3029RUS, 1/2016-09
Горелки для двух видов газа с W-FM 54. Дополнительный лист, 5101 RUS-1/2014
Внимание! Дополнительный лист. План проведения техобслуживания ж/т горелок WM 10 … 50, 5400 RUS-1/2017
Внимание! Дополнительный лист. План проведения техобслуживания газовых горелок WM 10 … 50, 5399 RUS-1/2017
Внимание! Дополнительный лист. План проведения техобслуживания комбинированных горелок WM 10 … 50, 5401 RUS-1/2017
WM — G20/2-A ZMI с W-FM 50. Горелки газовые, руководство по монтажу и эксплуатации, 2975 1/2015-07
Внимание! Изменение места установки реле макс. давления газа,дополнительный лист 5136RUS 1/2013
WM, GL, RGL. Горелки комбинированные, работа с керосином,дополнительный лист, 1210RUS-1/12
WM-GL20/3-A исп. ZM-T с W-FM 100/200. Горелки комбинированные, руководство по монтажу и эксплуатации, 2486RUS-2/2008
WM — GL20/3-A / ZM-T с W-FM 54. Горелки комбинированные, руководство по монтажу и эксплуатации, 2620RUS — 1/2019-05
WM-GL20/2-A исп. ZM-T с W-FM 100. Горелки комбинированные, руководство по монтажу и эксплуатации, 2485RUS-2/2008
WM-GL20/2-A исп. ZM-R с W-FM 54. Горелки комбинированные, руководство по монтажу и эксплуатации, 2638RUS-1/2020-05
WM-GL20/2-A исп. ZM-T с W-FM 54. Горелки комбинированные, руководство по монтажу и эксплуатации, 2619RUS-1/2013
WM-L20/3-A исп. R с W-FM 50. Горелки жидкотопливные, руководство по монтажу и эксплуатации, 2484RUS-1/2007
WM-L 20/3-A исп. T с W-FM 50. Горелки жидкотопливные, руководство по монтажу и эксплуатации, 2479RUS-1/2019-09
WM-L20/2-A исп. R с W-FM 100/200. Горелки жидкотопливные, руководство по монтажу и эксплуатации, 2529RUS-1/2007
WM-L20/2-A исп. T с W-FM 50. Горелки жидкотопливные, руководство по монтажу и эксплуатации, 2478RUS 2/2019-09
WM-G20/3-A исп. ZM-LN c W-FM 100/200. Горелки газовые, руководство по монтажу и эксплуатации, 2578RUS-1/2012
WM-G20/3-A исп. ZM c W-FM 100/200. Горелки газовые, руководство по монтажу и эксплуатации, 2507RUS, 1/2019-05
WM-G20/3-A исп. ZM c W-FM 50. Горелки газовые, руководство по монтажу и эксплуатации, 2481RUS, 1/2019-05
WM-G20/2-A исп. ZM-LN c W-FM 100/200. Горелки газовые, руководство по монтажу и эксплуатации, 2577RUS-1/2012
WM — G 20/2-A ZM (W-FM 100/200)Газовые горелки, руководство по монтажу и эксплуатации, 2506RUS — 1/2019-09
WM-G20/2-A исп. ZM-LN c W-FM 50. Горелки газовые, руководство по монтажу и эксплуатации, 2508RUS-1/2012
WM-G20/2-A исп. ZM c W-FM 50. Горелки газовые, руководство по монтажу и эксплуатации, 2480RUS-1/2019-09

WM 30

WM-GL30/1A/ZMR3LN (WFM 100-200). Комбинированная горелка, руководство по монтажу и эксплуатации, 2895RUS -02/2018
WM-S 30/3-A/R с W-FM 50. Горелки жидкотопливные, руководство по монтажу и эксплуатации, 3038RUS, 1/2018-11
WM — G30/1-A исп. ZM-3LN multiflam® с W-FM100/200. Газовые горелки, руководство по монтажу и эксплуатации, 2889RUS — 1/2018-01
WM — G30/2-A / ZM-LN с W-FM 100/200. Горелки газовые, руководство по монтажу и эксплуатации, 2694RUS — 1/2019-02
WM — L 30/3-A / R с W-FM 100/200. Горелки жидкотопливные, руководство по монтажу и эксплуатации, 2676RUS-1/2019-04
WM-S30/2-A / R с W-FM 50, Горелки жидкотопливные, руководство по монтажу и эксплуатации, 3037RUS-1/2018-11
WM — G 30/2-A исп. ZM-3LN multiflam® с W-FM100/200. Горелки газовые, руководство по монтажу и эксплуатации, 2890RUS- 1/2018-03
WM — G30/2-A / ZM c W-FM 100/200. Горелки газовые, руководство по монтажу и эксплуатации, 2625RUS-1/2018-08
WM — S30/1-A / R (W-FM 100/200), Горелки жидкотопливные, руководство по монтажу и эксплуатации, 3033RUS-1/2016-09
WM — L30/1-A исп. T с W-FM 100/200. Горелки жидкотопливные, руководство по монтажу и эксплуатации, 2679RUS-1/2014
WM — G30/1-A исп. ZM-LN c W-FM 50. Горелки газовые, руководство по монтажу и эксплуатации, 2690RUS-2/2014
WM — G 30/3-A / ZM-3LN multiflam с W-FM 200. Горелки газовые, руководство по монтажу и эксплуатации, 2891RUS- 1/2015
Горелки для двух видов газа с W-FM 54. Дополнительный лист, 5101 RUS-1/2014
WM-GS 30-3-A, исп. ZM-R с W-FM 100-200. Горелки комбинированные, руководство по монтажу и эксплуатации, 3032 RUS-1/2017
Внимание! Дополнительный лист. План проведения техобслуживания ж/т горелок WM 10 … 50, 5400 RUS-1/2017
Внимание! Дополнительный лист. План проведения техобслуживания газовых горелок WM 10 … 50, 5399 RUS-1/2017
Внимание! Дополнительный лист. План проведения техобслуживания комбинированных горелок WM 10 … 50, 5401 RUS-1/2017
WM-GS 30-1-A исп. ZM-R с W-FM 100-200. Горелки комбинированные, руководство по монтажу и эксплуатации, 3030 RUS-1/2017
WM-GS 30-2-A исп. ZM-R с W-FM 100-200. Горелки комбинированные, руководство по монтажу и эксплуатации, 3031 RUS-1/2017
WM-L30/2-A исп. Т с W-FM 100/200. Горелки жидкотопливные, руководство по монтажу и эксплуатации, 2680RUS 2/2014
WM-G30/3-A исп. ZM-LN c W-FM 50. Горелки газовые, руководство по монтажу и эксплуатации, 2692RUS-2/2014
WM-G 30/2-A ZM-LN (W-FM50). Газовые горелки, руководство по монтажу и эксплуатации, 2691RUS — 1/2019-10
Внимание! Изменение места установки реле макс. давления газа, дополнительный лист, 5136RUS 1/2013
Внимание! Изменение места установки реле макс. давления газа,дополнительный лист 5136RUS 1/2013
WM-G30/1-A исп. ZM-LN (W-FM 100/200). Газовые горелки, руководство по монтажу и эксплуатации, 2693RUS-1/2014-12
WM, GL, RGL. Горелки комбинированные, работа с керосином, дополнительный лист, 1210RUS-1/12
WM-G30/4-A исп. ZM (W-FM 50). Газовые горелки, руководство по монтажу и эксплуатации, 2862RUS-1/2013
WM-GL30/3-A исп. ZM-R с W-FM 100/200. Горелки комбинированные, руководство по монтажу и эксплуатации, 2636RUS-1/2010
WM — GL 30/3-A / ZM-R (W-FM 54). Комбинированная горелка, руководство по монтажу и эксплуатации, 2633RUS — 1/2019-04
WM-GL30/2-A исп. ZM-R с W-FM 54. Горелки комбинированные, руководство по монтажу и эксплуатации, 2632RUS-1/2010

WM 50

WM-L50/3-A исп. R с W-FM200. Горелки жидкотопливные, руководство по монтажу и эксплуатации, 3151RUS-1/2019-09
WM-GL 50/3-A ZM-R-NR (W-FM200). Комбинированная горелка, руководство по монтажу и эксплуатации, 3149RUS — 1/2019-09
WM-G 50/3-A ZM-NR (W-FM200). Газовые горелки, руководство по монтажу и эксплуатации, 3150RUS — 1/2019-09
WM — L50/2-A / R с W-FM 100/200, Горелки жидкотопливные, руководство по монтажу и эксплуатации, 2953RUS-1/2018-03
Внимание! Дополнительный лист. План проведения техобслуживания ж/т горелок WM 10 … 50, , 5400 RUS-1/2017
Внимание! Дополнительный лист. План проведения техобслуживания газовых горелок WM 10 … 50, 5399 RUS-1/2017
Внимание! Дополнительный лист. План проведения техобслуживания комбинированных горелок WM 10 … 50, 5401 RUS-1/2017
WM-G50/2-A исп. ZM-NR с W-FM 100/200. Газовые горелки, руководство по монтажу и эксплуатации, 2948RUS-1/2018-01
Внимание! Изменение места установки реле макс. давления газа, дополнительный лист, 5136RUS 1/2013
Внимание! Изменение места установки реле макс. давления газа, дополнительный лист, 5136RUS 1/2013
WM-GL50/2-A исп. ZM-R-NR с W-FM 100/200. Горелки комбинированные, руководство по монтажу и эксплуатации, 2950RUS-1/2014
WM — G50/1-A исп. ZM-NR с W-FM 100/200. Горелки газовые руководство по монтажу и эксплуатации, 2947RUS-1/2017-12
WM-GL50/1-A исп. ZM-R-NR с W-FM 100/200. Горелки комбинированные, руководство по монтажу и эксплуатации, 2949RUS-1/2014

Типоряд 30—70

G70/2-A ZM-1LN (W-FM 100/200), Горелки газовые, руководство по монтажу и эксплуатации, 2727RUS, 1/2011-07
RMS 50/2-A исп. ZM с W-FM 100/200. Горелки жидкотопливные, руководство по монтажу и эксплуатации, 2769RUS-1/2013
RMS 60/2-A исп. ZM с W-FM 100/200. Горелки жидкотопливные, руководство по монтажу и эксплуатации, 2708RUS-1/2018
G70/1-B 3LN multiflam® (55 Гц). Горелки газовые, руководство по монтажу и эксплуатации, 5073RUS, 1/2018-05
Комбинированные горелки RGL70/1-B 3LN multiflam® с W-FM 100/200, 2401RUS 1/2015-01
Комбинированные горелки RGL70/1-B 3LN multiflam® (55 Гц), 5072RUS, 1/2015-01
G70/2-A ZM-1SF c W-FM 100/200, Горелки газовые, руководство по монтажу и эксплуатации, 2823RUS, 1/2015-01
G70/4-A исп. ZM-NR c W-FM 200. Горелки газовые, руководство по монтажу и эксплуатации, 2586RUS-1/2018
G70/3-A исп. ZM-NR с W-FM 100/200. Горелки газовые, руководство по монтажу и эксплуатации, 2585RUS-1/2018
Комбинированные горелки RGL30/2-A исп. ZM-NR с W-FM 100/200, 2801RUS-1/2012-06
Комбинированные горелки RGL70/4-A/ZM-NR (W-FM 200), 2580RUS-1/2015
L, RL 1–11 и 30–70. Горелки жидкотопливные, работа с керосином,дополнительный лист 1209RUS-1/12
Внимание! Изменение места установки реле макс. давления газа, дополнительный лист 5136RUS-1/2013
Горелки для двух видов газа с W-FM100/200, дополнительный лист 5100RUS-1/14
Комбинированные горелки RGMS 70/2-A исп. ZM-NR, 2505RUS-1/2007
RMS 70/2-A исп. ZM с W-FM 100/200. Горелки жидкотопливные, руководство по монтажу и эксплуатации, 2715RUS-1/2011
Комбинированные горелки RGL70/2-A исп. ZM-1LN c W-FM 100/200, 2719RUS-1/2011
Газовые горелки G70/2-A исп. ZM-LN c W-FM 100/200, 2696RUS-1/2011
Комбинированные горелки RGMS70/1-B исп. ZM-NR с W-FM 100/200, 2710RUS-1/2013
Комбинированные горелки RGL70/1-B исп. ZM-NR с W-FM 100/200, 2686RUS-1/2010
Газовые горелки G70/1-B исп. ZM-NR с W-FM 100/200, 2685RUS-1/2010
Газовые горелки G70/1-B исп. ZM-LN с W-FM 100/200, 2684RUS-1/2010
Комбинированные горелки RGMS60/2-A исп. ZM-NR с W-FM 100/200, 2705RUS-1/2013
Комбинированные горелки RGL60/2-A исп. ZM-NR с W-FM 100/200, 2699RUS-1/2011
Газовые горелки G60/2-A исп. ZM-NR с W-FM 100/200, 2697RUS-1/2011
Комбинированные горелки RGMS50/2-A исп. ZM-NR c W-FM 100/200, 2782RUS-1/2013
Комбинированные горелки RGL50/2-A исп. ZM-NR c W-FM 100/200, 2726RUS-1/2011
Газовые горелки G50/2-A исп. ZM-NR с W-FM 100/200, 2724RUS-1/2011
Газовые горелки G50/1-B исп. ZM-NR с W-FM 100/200, 2752RUS-1/2011
Комбинированные горелки RGMS40/2-A исп. ZM-NR с W-FM 100/200, 2806RUS-1/2013

Типоряд WK

WKG 50/2-A ZM(H)-NR с W-FM 100/200. Горелки газовые, руководство по монтажу и эксплуатации, 2846RUS, 1/2019-04
WKGL70/1-B ZM(H) (W-FM 100/200), Горелки комбинированные, руководство по монтажу и эксплуатации, 2929RUS -1/2014-03
WKG 70/2-A исп. ZM(H)-1SF с W-FM 100/200. Горелки газовые, руководство по монтажу и эксплуатации, 2790RUS-1/2014-11
WKGL70/2-A ZM(H)-1SF (W-FM 100/200). Горелки комбинированные, руководство по монтажу и эксплуатации, 2792RUS-1/2014
WKG 40/2-A исп. ZM(H) с W-FM 100/200. Горелки газовые, руководство по монтажу и эксплуатации, 2866RUS-1/2013-03
WKG50/2-A ZM(H) (W-FM 100/200), Горелки газовые, руководство по монтажу и эксплуатации, 2832RUS-1/2013-02
Арматура низкого давления для горелок WK80 с регулятором SKP25, 5260 RUS 1/2015
Арматура высокого давления для WK80, 5259 RUS 1/2015
WKG80/6-A исп. ZM(H)-3SF с W-FM 100/200. Горелки газовые, руководство по монтажу и эксплуатации, 2967RUS 1/2015
WKG 70/1-B исп. ZM(H)- NR. Горелки газовые с менеджером горения W-FM 100/200, 2779-1/2014-11
WКGL70/1-В исп. ZM(H) с W-FM 100/200. Горелки комбинированные, руководство по монтажу и эксплуатации 2929RUS-1/2014
WKGMS 80/3-А исп. ZM(H)-1SF c W-FM 100/200. Горелки комбинированные, руководство по монтажу и эксплуатации, 2829RUS-1/2013
WKG 70/2, WKGL 70/2 . Горелки газовые, комбинированные, исполнение 1LN, 1281RUS-1/00
WK 40-70. Горелки газовые, комбинированные, ж/топливные, руководство по планированию, 1124RUS-1/01
WK 40-70. Горелки газовые, комбинированные, ж/топливные, руководство по планированию, 1124RUS-1/01
WKL70/3-А исп. NR. Горелки жидкотопливные, руководство по монтажу и эксплуатации 2520RUS-1/07
Расширение диапазона мощности WKGL80/3-A исп. ZM-NR, дополнительный лист 5185RUS-1/2014
Внимание! Изменение места установки реле макс. давления газа, дополнительный лист 5136RUS-1/2013
WКGL70/3-A исп. ZMH-NR. Горелки комбинированные, руководство по монтажу и эксплуатации 2522RUS-1/2011
Внимание! Изменение места установки реле макс. давления газа, дополнительный лист 5136RUS-1/2013
WK4. Горелки газовые, комбинированные, жидкотопливные, руководство по планированию 879RUS-1/02
WKG80/4-A ZM(H)-VSF с W-FM 100/200. Горелки газовые, руководство по монтажу и эксплуатации 2913RUS 1-/2020-04
WKG80/5-A ZM(H)-VSF с W-FM 100/200. Горелки газовые, руководство по монтажу и эксплуатации 2914RUS-1/2013
MS, RMS, WKMS. Горелки мазутные, руководство по обслуживанию, 610RUS-1/97
WKMS 80/3-A исп. ZM(H) c W-FM 100/200. Горелки жидкотопливные, руководство по монтажу и эксплуатации, 2581RUS-1/2011
WKGMS 80/3-А исп. ZM-NR. Горелки комбинированные, руководство по монтажу и эксплуатации, 2449RUS-1/2011
WKGL 80/3-А исп. NR. Горелки комбинированные, руководство по монтажу и эксплуатации, 2448RUS-1/2011
WKG 80/3-А, исп. NR. Горелки газовые, руководство по монтажу и эксплуатации, 2456RUS-1/2011
WKL 80/3-А исп. NR. Горелки жидкотопливные, руководство по монтажу и эксплуатации, 2457RUS-1/2011
WKGL 70/3A исп. NR. Горелки промышленные, руководство по монтажу и эксплуатации, 2522RUS-1/2011

Типоряд WKmono

WKmono-GL 80/1-B ZM-R-NR с W-FM100/200, Горелки комбинированные, руководство по монтажу и эксплуатации, 3178RUS — 1/2019-12
WKmono-G80/2-A/ZM-VSF c W-FM 100/200. Газовые горелки, руководство по монтажу и эксплуатации, 3074RUS, 1/2017-05
Разворот воздухозаборника горелок WKmono-(G)L80 на 90° / 180°, 5511RUS, 1/2017-10
Разворот воздухозаборника горелок WKmono-G80 на 90° / 180°, 5512RUS, 1/2017-10
WKmono-L80/1-A исп. R c W-FM 100/200. Горелки жидкотопливные, руководство по монтажу и эксплуатации 3011RUS-1/2016
WKmono-G 80/2-A исп. ZM-3LN с W-FM 100/200. Горелки газовые, руководство по монтажу и эксплуатации, 3001RUS, 1/2016-04
WKmono-GL80/2-A/ZM-R-NR c W-FM 100/200. . Комбинированные горелки, руководство по монтажу и эксплуатации, 2998 2/2016-03
WKmono-GL80/1-A / ZM-R-NR с W-FM 100/200. Комбинированные горелки, руководство по монтажу и эксплуатации 2995RUS-2/2016-03
WKmono-G80/1-A / ZM-NR (W-FM 100/200), Горелки газовые, руководство по монтажу и эксплуатации, 2996RUS-2/2016-03
WKmono-G80/2-A / ZM-NR (W-FM 100/200). Горелки газовые, руководство по монтажу и эксплуатации, 2997RUS-1/2015-12

Полностью автоматическая газовая горелка Вайсхаупт — Weishaupt WG20 N/1-C Z-LN, двухступенчатая, с диапазоном тепловой мощности от 35 до 200 кВт. Горелочное устройство может работать на природном и магистральном газе, при этом, перенастройка производится ручным способом. Горелка адаптирована под низкое давление, и может функционировать при давлении газа 10 — 300 мБар. Блок розжига микропроцессорный, контролирует всю работу системы. Газовый клапан (рампа) идет в комплекте поставки. Мы рекомендуем купить газовую горелку Weishaupt WG20 N/1-C Z-LN для котла мощностью до 200 кВт, отопления площадей до 2000   м² . Все горелки Вайсхаупт серии W адаптированы к применению в российских условиях, имеют сертификацию ГОСТ Р, разрешение на применение Ростехнадзора.

Характеристики

Артикул WG20 N/1-C Z-LN
Вес 26.00 кг
Мощность горелки 35 – 200 кВт
Вид топлива Магистральный газ
Гарантия 1 лет
Давление газа 10-300 мбар
Питание 220
Производство Германия
Расход топлива 7,5-18 л/час
Тип горелки Двухступенчатая
Типоразмер газовой линии 3/4″

  • Описание

  • Файлы для скачивания

  • Отзывы

Газовая двухступенчатая горелка Вайсхаупт для котла мощностью до 200 кВт.

Расшифровка обозначений:
Пример: WG10N/-1DLN
Типоряд: компактные горелки
G — Топливо: газ
10 — Типоразмер
N — природный газ
F — сжиженный газ
1 — Класс мощности
D — Тип конструкции
LN — Смесительное устройство: LowNO
Технические данные:
— Мощность: 25 – 110 кВт;
— Полностью автоматическая газовая горелка;
— Микропроцессорный менеджер горения;
— Топливо: природный газ, сжиженный газ;
— Давление подключения газа: 10 – 300 мбар;
— Вид регулирования: одноступенчатая, двухступенчатая, плавно-двухступенчатая, модулируемая;
— Исполнение: LN (Low NOx);
— В объем поставки входит комплект газовой арматуры.
— Исполнение LN — одноступенчатая;
— Исполнение Z-LN — двухступенчатая;
— Исполнение ZM-LN — модулируемая.

Отзывы о товаре

Отзывов об этом товаре еще нет. Вы можете стать первым, кто оставит отзыв!

Получите дисконтную карту при первой покупке.

Есть наша дисконтная карта?

Тогда мы можем предложить нужное вам оборудование по выгодной для вас цене!
С вами свяжется ваш персональный менеджер.
Просто оставьте свой номер телефона или электронную почту и укажите номер карты.

Газовая горелка Weishaupt (Вайсхаупт) WG20N/1-C Z-LN 1″ (МБ 507) работает на природном газе E/LL. Горелка оборудована множеством электросистем. Многофункциональный газовый мультиблок, включающий: два магнитных клапана класса А, встроенный регулятор давления газа, фильтр-грязевик, реле давления газа. Двигатель горелки вращает вентиляторное колесо для нагнетания воздуха.

Характеристика Значение
Управляющий газовый блок мультиблок 507
Min давление, мБар 11
Потребляемая мощность, Вт 366
Напряжение/частота тока, В/Гц 220/50
Max давление, мБар 300
Число ступеней регулирования 2
Вид топлива Газ
Min мощность, кВт 35
Max мощность, кВт 200
Гарантия 2 года
Вес, кг 20

  • Прайс-лист на продукцию завода Weishaupt

    Прайс-лист на продукцию

  • характеристики. Горелки серии W 5-40

  • Каталог продукции бренда Weishaupt

    Каталог продукции Weishaupt

  • Опросный лист на горелки производства Weishaupt

    Опросный лист на горелки Weishaupt

  • Брошюра на оборудование завода Weishaupt

    Брошюра на оборудование Weishaupt

  • БОГАТАЯ ИСТОРИЯ

    Компания Weishaupt существует более 80 лет. На сегодняшний день фирма насчитывает более 2500 сотрудников. Около половины из них работают на головном предприятии в г. Швенди, другая половина – в филиалах в Германии и других странах мира.Завод площадью 60 тысяч м2 ежегодно выпускает свыше 150 тысяч горелок.

  • РАЗВИТИЕ И ИССЛЕДОВАНИЯ

    Исследования и развитие занимают ведущее место в компании Weishaupt. Открытый в 1962 году институт развития и исследования Weishaupt, благодаря своему уникальному оборудованию, имеет все возможности для дальнейшего совершенствования конструкции горелок.

  • ЭФФЕКТИВНОСТЬ

    Горелки Weishaupt – это надежное оборудование с современным дизайном и большим сроком службы. Лучшие материалы, серийный выпуск и многоуровневый контроль гарантируют постоянное качество. Благодаря высокому КПД горелок тепловая энергия топлива используется максимально эффективно.

  • Горелки модели W 5-40 WEISHAUPT

    Горелки модели W 5-40

    WG 5, WL5, WG 10, WL10 и др.

  • Горелки WM Monarch WEISHAUPT

    Горелки WM Monarch

    WM-G 10, WM-L 20, WM-GL 50 и др.

  • Жидкотопливные горелки WEISHAUPT

    Жидкотопливные горелки

    WM-S101-AZ и др.

  • Горелки комбинированные WEISHAUPT

    Горелки комбинированные

    WM-GS202-A ZM-R 1 и др.

  • Моноблочные горелки WEISHAUPT

    Моноблочные горелки

    G, GL, RGL 30-70, LN, 1LN и др.

  • Горелки Monarch 1-11 WEISHAUPT

    Горелки Monarch 1-11

    G, L, RL, M, RGMS, 1-7, 5-11 и др.

  • Промышленные горелки WEISHAUPT

    Промышленные горелки

    WK 40-70, WK 80 и др.

  • Принадлежности для горелок WEISHAUPT

    Принадлежности для горелок

    Регуляторы, клапаны и др.

  • Котлы и принадлежности WEISHAUPT

    Котлы и принадлежности

    WTC-GW, Kompakt, WTC-GB

Обратитесь к нам или региональному дилеру для получения более подробной информации о сертификатах, характеристиках, отзывах, стоимости, наличии на складе и сроках поставки оборудования Weishaupt.

Мы гарантируем ответ в течение 8 рабочих часов!

адрес для заявок: wtp@nt-rt.ru

Задайте вопрос прямо сейчас:

Перейти к содержанию

Опубликовано 17 февраля, 2022 Обновлено 17 февраля, 2022

Содержание

  1. Wg30n 1 c инструкция по монтажу
  2. Газовые горелки Weishaupt серии WM:
  3. Газовые горелки Weishaupt серии WG:
  4. Газовые горелки Weishaupt серии G:
  5. Газовые горелки Weishaupt серии WK:
  6. Дополнительная документация Weishaupt :
  7. Жидкотопливные горелки Weishaupt . Руководства по эксплуатации:
  8. Жидкотопливные горелки Weishaupt серий RMS, WL, WKL:
  9. Жидкотопливные горелки Weishaupt серий WML, WHS:
  10. Комбинированные горелки Weishaupt :

Wg30n 1 c инструкция по монтажу

Если Вы считаете, что компетентность стоит дорого, то попробуйте некомпетентность – она обойдётся вам гораздо дороже.

Йохан Стаель фон Хольстайн

Газовые горелки Weishaupt серии WM:

  • Биогазовая горелка Weishaupt WM-G(L) 10/1-A.
    Руководство. Дополнительный лист.
  • Биогазовая горелка Weishaupt WM-G(L) 10/3-A.
    Руководство. Дополнительный лист.
  • Газовая горелка Weishaupt WM-G 10/1-A/ZM c W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 10/1-A/ZM c W-FM 100, 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 10/1-A/ZM-LN c W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 10/1-A/ZM-LN c W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 10/1-A/ZMI c W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 10/2-A/ZM c W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 10/2-A/ZM c W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 10/2-A/ZM-LN c W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 10/2-A/ZMI c W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 10/3-A/ZM c W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 10/3-A/ZM c W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 10/3-A/ZM-LN c W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 10/3-A/ZM-LN c W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 10/3-A/ZMI c W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 10/4-A/ZM c W-FM50.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G10/4-A/ZM c W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 10/4-A/ZMI c W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 20/2-A/ZM c W-FM 50
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 20/2-A/ZM c W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 20/2-A/ZM-LN c W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 20/2-A/ZM-LN c W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 20/2-A ZMI c W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 20/3-A/ZM c W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 20/3-A/ZM c W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 20/3-A/ZM-LN c W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 20/3-A/ZM-LN c W-FM 100, 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 30/1-A/ZM с W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 30/1-A/ZM с W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 30/1-A/ZM-LN с W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 30/2-A/ZM с W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 30/2-A/ZM с W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 30/2-A/ZM-LN с W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 30/3-A/ZM с W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 30/3-A/ZM с W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 30/3-A/ZM-LN с W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 30/3-A/ZM-3LN с W-FM 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 30/4-A/ZM с W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 30/4-A/ZM с W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 50/1-A/ZM-NR c W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WM-G 50/2-A/ZM-NR c W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.

Газовые горелки Weishaupt серии WG:

  • План проведения техобслуживания горелок Weishaupt WG5. 40.
    Дополнительный лист.
  • Газовые горелки Weishaupt WG5. /1-A LN.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WG10. /0-D ZM-LN.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WG10. /1-D LN.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WG10. /1-D Z-LN.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WG10. /1-D ZM-LN.
    Инструкция по монтажу и эксплуатации
  • Газовая горелка Weishaupt WG20. /1-C, LN (LowNOx).
    Инструкция по монтажу и эксплуатации
  • Газовая горелка Weishaupt WG20. /1-C, Z-LN.
    Инструкция по монтажу и эксплуатации
  • Газовая горелка Weishaupt WG20. /1-C, ZM-LN.
    Инструкция по монтажу и эксплуатации
  • Газовая горелка Weishaupt WG30. /1-C ZM-LN.
    Инструкция по монтажу и эксплуатации
  • Газовая горелка Weishaupt WG30. /1-C и Weishaupt WG40. /1-A исп. ZM-LN (LowNOx)
    Инструкция по монтажу и эксплуатации
  • Газовая горелка Weishaupt WG30N/1-C и Weishaupt WG40N/1-A исп. ZM-LN (LowNOx) c частотным регулированием для природного газа.
    Инструкция по монтажу и эксплуатации
  • Газовая горелка Weishaupt WG40. /1-A исп.ZM-LN.
    Инструкция по монтажу и эксплуатации

Газовые горелки Weishaupt серии G:

  • Газовая горелка Weishaupt G50/1-B ZM-NR (W-FM 100-200).
    Руководство по монтажу и эксплуатации.
  • Газовая горелка Weishaupt G50/2-A ZM-NR (W-FM 100-200).
    Руководство по монтажу и эксплуатации.
  • Газовая горелка Weishaupt G60/2-A ZM-NR (W-FM 100-200).
    Руководство по монтажу и эксплуатации.
  • Газовая горелка Weishaupt G70/1-B 3LN (55 Hz).
    Дополнительный лист.
  • Газовая горелка Weishaupt G70/1-B ZM-LN (W-FM 100-200).
    Руководство по монтажу и эксплуатации.
  • Газовая горелка Weishaupt G70/1-B ZM-NR (W-FM 100-200).
    Руководство по монтажу и эксплуатации.
  • Газовая горелка Weishaupt G70/2-A ZM-LN (W-FM 100-200).
    Руководство по монтажу и эксплуатации.
  • Газовая горелка Weishaupt G70/3-A ZM-NR (W-FM 100-200).
    Руководство по монтажу и эксплуатации.
  • Газовая горелка Weishaupt G70/4-A ZM-NR (W-FM 200).
    Руководство по монтажу и эксплуатации.

Газовые горелки Weishaupt серии WK:

  • Газовые горелки Weishaupt WK4.
    Техническая документация.
  • Горелки Weishaupt WK40 — WK70.
    Техническая документация.
  • Газовая горелка Weishaupt WKG40/2-A ZM(H) c W-FM100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WKG 50/2-A ZM (H) c W-FM100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WKG70/1-A ZM(H)-NR c W-FM100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WKG70/2-A ZM(H)-1SF c W-FM100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WKG70.2-A 1LN (LowNOx).
    Инструкция по монтажу и эксплуатации.
  • Газовые и комбинированные горелки Weishaupt WKG 70/2 и WKGL 70/2, исп. 1LN (Low NOx).
    Дополнительные листы.
  • Газовая горелка Weishaupt WKG70/3-A ZM(H)-NR c W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WKG80/3-A ZM(H)-NR c W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WKG80/4-A ZM(H)-VSF c W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WKG80/5-A ZM(H)-VSF c W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WKG80/6-A ZM(H)-3SF c W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Арматура высокого давления для горелок Weishaupt WK80.
  • Газовая горелка Weishaupt WKmono-G80/1-A/ZM-NR с W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WKmono-G80/2-A/ZM-3LN с W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Газовая горелка Weishaupt WKmono-G80/2-A/ZM-NR с W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.

Дополнительная документация Weishaupt :

  • Горелки Weishaupt для двух видов газа с W-FM 54.
    Дополнительный лист.
  • Горелки Weishaupt для двух видов газа с W-FM 100. 200.
    Дополнительный лист.

Жидкотопливные горелки Weishaupt . Руководства по эксплуатации:

Почти 70 лет опыта. В каждой горелке.

Weishaupt Company

Жидкотопливные горелки Weishaupt серий RMS, WL, WKL:

  • Жидкотопливные горелки Weishaupt RMS 70/2-A ZM (W-FM 100. 200).
    Руководство по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WL5-A-H-1LN (LowNOx).
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WL5/1-B.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WL 5/1-B, исп.H-2LN (LowNOx).
    Руководство по монтажу и эксплуатации.
  • Жидкотопливные горелки Weishaupt WL 5/1-B, WL 5/2-B, WL 5/1-B исп.H.
    Руководство по монтажу и эксплуатации.
  • Жидкотопливные горелки Weishaupt WL 5/1-A, WL 5/1-A исп. Н; WL 5/2-A, WL 5/2-A, исп.H.
    Руководство по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WL5/2-B.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WL10/2-D Z.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливныя горелка Weishaupt WL10/3-D.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WL10/3-D Z.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WL20/1-C.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WL20/1-C Z-1LN.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WL 20/1-C, исп. Z и WL20/2-C, исп.Z.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WL20/2-C.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WL 30-C и WL40-A.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WL 30Z-C и WL40Z-A исп.LN (LowNOx).
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WL 30Z-C.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WL 30Z-C для технологических установок.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WL40Z-A на технологической установке.
    Дополнительный лист.
  • Жидкотопливная горелка Weishaupt WKL70/3-A.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WKL 80/3-A ZM(H) c W-FM 100. 200.
    Инструкция по монтажу и эксплуатации
  • Жидкотопливная горелка Weishaupt WKmono-L80/1-A/R с W-FM 100/200.
    Инструкция по монтажу и эксплуатации
  • Разворот воздухозаборника жидкотопливных горелок Weishaupt WKmono-(G)L80, на 90° / 180°.
    Инструкция по монтажу

Жидкотопливные горелки Weishaupt серий WML, WHS:

  • Жидкотопливная горелка Weishaupt WM-L 10/1-A/T c W-FM50.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WM-L 10/2-A/R.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WM-L 10/2-A/R c W-FM50.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WM-L 10/2-A/T.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WM-L 10/2-A/T c W-FM50.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WM-L 10/3-A/R.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WM-L 10/3-A/T.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WM-L 10/3-A/T с W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WM-L 10/4-A/R.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WM-L 10/4-A/T.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WM-L 10/4-A/T с W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WM-L 10/4-A/ZM c W-FM50.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WM-S10/1-A/Z с W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WM — S10/2-A/Z с W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WM-S10/3-A/T с W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WM-L 20/1-A/T с W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WM-L 20/2-A/T с W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WM-L 20/2-A/R с W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WM-L 20/3-A/T с W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WM-L 20/3-A/R с W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WM-L 30/1-A/R с W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WM-L 30/1-A/R с W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WM-S 30/1-A/R с W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WM-L 30/1-A/T с W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WM-L 30/2-A/T с W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WM-L 30/3-A/R с W-FM 50.
    Инструкция по монтажу и эксплуатации.
  • Жидкотопливная горелка Weishaupt WM-L 50/2-A/R c W-FM 100. 200.
    Инструкция по монтажу и эксплуатации.
  • План проведения техобслуживания горелок Weishaupt WL 5 . 40.
    Дополнительный лист.
  • Руководство по обслуживанию жидкотопливных горелок Weishaupt серий WL30 и WL40 исполнения Z-C.
  • План проведения техобслуживания жидкотопливных горелок Weishaupt WM 10 . 50WM_10_50_5400.
  • Жидкотопливные горелки Weishaupt серии L, RL 1-11 + 30. 70.
    Работа с керосином. Дополнительный лист.
  • Жидкотопливная горелка Weishaupt Monarch серии MS, RMS, WKMS.
    Руководство по обслуживанию.
  • Постоянная работа двигателя, горелки Weishaupt WL.
    Инструкция по монтажу.

Комбинированные горелки Weishaupt :

Будущее энергетических технологий. Станьте частью сейчас.

Weishaupt Company

Источник

Понравилась статья? Поделить с друзьями:

А вот и еще наши интересные статьи:

  • Скачать руководства по ubuntu
  • Harvard business school press руководство по улучшению бизнес процессов
  • Ооо регион руководство
  • Сементал инструкция по применению цена отзывы аналоги цена
  • Алезан паста для лошадей инструкция по применению

  • 0 0 голоса
    Рейтинг статьи
    Подписаться
    Уведомить о
    guest

    0 комментариев
    Старые
    Новые Популярные
    Межтекстовые Отзывы
    Посмотреть все комментарии